UPPERSTRUCTURE / Control Valve

17. Install O-rings (59) (2 used) to plugs (58) (2 used).

Install poppets (61) (2 used), springs (60) (2 used)

and plugs (58) (2 used) into housing (8).

: 24 mm

: 88 to 98 N⋅m

(9 to 10 kgf⋅m, 65 to 72 lbf⋅ft)

IMPORTANT: Apply LOCTITE #271 to the screws

on spool ends (22).

18. Attaching wooden pieces to both sides of spools

(4) to (7) and (15) to (19), secure each spool in a

vise. Install spring seat (23), spring (24), spring

seat (23) and spool end (22) to each of the

spools.

:5 mm

: 19 to 22 N⋅m

(1.9 to 2.2 kgf⋅m, 13.5 to 16 lbf⋅ft)

NOTE: Spring (24) can be compressed by hand.

19. Install spools (4) to (7), (15) to (19) into housing

(8). Install O-rings (3) (9 used) and cover (2) to

the housing. Secure the cover with socket bolts

(1) (3 used) and (12) (8 used).

:5 mm

: 8.8 to 10.8 N⋅m

(0.9 to 1.1 kgf⋅m, 6.5 to 8.0 lbf⋅ft)

20. Install O-rings (3) (9 used) and cover (9) to

housing (8). Secure the cover with socket bolts

(12) (11 used).

:5 mm

: 8.8 to 10.8 N⋅m

(0.9 to 1.1 kgf⋅m, 6.5 to 8.0 lbf⋅ft)

NOTE: Refer to page W2-5-3 for socket bolts (12).