UPPERSTRUCTURE / Pilot Valve

Removal

1. Remove bolts (2) (4 used), spring washers (3) (4

used) and plane washers (4) (4 used) to remove

under cover (1).

: 17 mm

4

3

1

2

W1CC-02-07-003

2. Loosen bolts (5) (4 used) to remove pedal (6),

levers (17) and (18).

: 17 mm

IMPORTANT: Attach identification tags on all disconnected

hoses to aid in reassembly.

3. Disconnect hoses (7 to 12).

: 19 mm

NOTE: Attach a cap on each disconnected hose

end.

4. Remove socket bolts (15) (2 used), spring washers

(14) (2 used) and plane washer (13) (2 used)

to remove pilot valve (16).

:8 mm

17

5

6

18

15

14

13

16

5

6

15

14

13

7

12

11

10

9

8

W1CC-02-07-004

7 - Hose P : From the pilot shut-off valve

8 - Hose T : To the pilot shut-off valve

9 - Hose 2-10 : To the control valve 1 port 10

(right travel forward)

10 - Hose 1-TR9: To control valve port 9

(right travel reverse)

11 - Hose 4-11 : To control valve port 11

(left travel reverse)

12 - Hose 3-12: (To control valve 1 port 12

(left travel forward)

W2-7-10