UPPERSTRUCTURE / Pilot Shut-Off Valve

Removal

1. Remove bolts (3) (6 used), spring washers (2) (6

used) and plane washers (1) (6 used). Remove

under cover (4).

: 17 mm

4

1

2

3

IMPORTANT: Do not turn rod end (8), or

adjustment is necessary.

2. Remove socket bolt (5), plane washer (6), nut

(10) and spring washer (9).

: 10 mm

:5 mm

7

8

10

9

W1CC-02-07-003

IMPORTANT: Attach identification tags to the

hydraulic hoses for reassembly.

3. Disconnect hoses (12 to 22) from pilot shut-off

valve (7).

: 19, 22 mm

5

6

21

22

W197-02-08-001

4. Loosen socket bolts (11) (2 used). Then, remove

pilot shut-off valve (7).

:8 mm

20

11

12

19

18

17

15

14

16

11 - Socket Bolts (2 used)

12 - Hose T4 : To hydraulic oil tank

13 - Hose BT : From blade pilot valve

14 - Hose PB : From solenoid valve unit

15 - Hose T3: From right pilot valve

16 - Hose HT : To shockless valve

17 - Hose T2: From left pilot valve

18 - Hose BP : To blade pilot valve

19 - Hose P1 : To left pilot valve

20 - Hose P2: To right pilot valve

21 - Hose PT : From travel pilot valve

22 - Hose PP: To travel pilot valve

13

W1CC-02-08-003

W2-8-2