UPPERSTRUCTURE / Pilot Valve

IMPORTANT: Attach identification tags on all disconnected

hoses to aid in reassembly.

7. Disconnect hoses (24 to 29) and attach a cap on

each disconnected hose end.

: 19 mm

21

8. Remove bolt (9) with spring pin (8), spring washer

(11), plane washer (12) and bolts (10) (3 used) to

remove pilot valve (21).

: 13 mm

28

29

24

25

26

27

W178-02-07-004

Installation

1. Install spring washer (11) and plane washer (12)

to bolt (9) with spring pin (8). Install pilot valve (21)

to the console with bolts (9) and (10).

: 13 mm

: 10 N⋅m (1.0 kgf⋅m, 7.2 lbf⋅ft)

24 - Hose T2: To pilot shut-off valve

25 - Hose F : To pilot piping coupler bracket

port F (right swing)

26 - Hose C : To pilot piping coupler bracket

port C (arm roll-out)

27 - Hose P1: From pilot shut-off valve

28 - Hose E : To pilot piping coupler bracket

port E (left swing)

29 - Hose D : To pilot piping coupler bracket

port D (arm roll-in)

NOTE: Piping location shows that of ISO pattern.

2. Connect hoses (24 to 29) to pilot valve (21).

: 19 mm

: 29.5 N⋅m (3 kgf⋅m, 21.5 lbf⋅ft)

21

8

9

10

11

12

W178-02-07-003

W2-7-7