Vocabulary Exercise: Completion<br />

Complete the paragraphs that follow by filling in appropriate words <strong>and</strong> phrases.<br />

Chapter 5: LAN Design <strong>and</strong> Switches 235<br />

The first step in designing a LAN is to establish <strong>and</strong> document the goals of the design.<br />

Most LANs are designed to meet four major requirements:<br />

■ Functionality, which enables users to meet their job requirements with speed <strong>and</strong> reliability<br />

■ Scalability, which means that the network should be designed with future growth in mind<br />

■ Adaptability, which means that the network design will easily incorporate new technologies<br />

■ Manageability, which facilitates network monitoring<br />

Servers can be categorized into two distinct classes:<br />

■ Enterprise servers support all the users on the network by offering services such as e-mail, DNS, <strong>and</strong><br />

corporate intranet access.<br />

■ Workgroup servers support a specific set of users, offering services such as word processing <strong>and</strong> file<br />

sharing specific to that group’s needs.<br />

Enterprise servers should be placed in the MDF, <strong>and</strong> workgroup servers should be placed in the IDF closest<br />

to the users who need it.<br />

One of the most important components to consider when designing a network is the cables/cabling/cable<br />

plant because the physical layer is the cause of most network problems.<br />

Fiber-optic cable should be used in the backbone <strong>and</strong> risers in all cable designs. Category 5e or Category 6<br />

UTP cable should be used in the horizontal runs. The cable upgrade should take priority over any other<br />

necessary changes.<br />

The TIA/EIA-568-A st<strong>and</strong>ard specifies that every device connected to the network should be linked to a<br />

central location with horizontal cabling. In a simple star topology, this central location is the MDF (acronym)<br />

<strong>and</strong> includes one or more HCCs used to connect the Layer 1 horizontal cabling coming into the wiring<br />

closet from work areas to the Layer 2 LAN switch inside the wiring closet.<br />

In larger network environments, multiple wiring closets are often needed. These extra or secondary wiring<br />

closets are referred to as IDFs.<br />

A VCC in each wiring closet is used to interconnect the various IDFs to the central MDF. The type of<br />

backbone or vertical cabling used is usually fiber-optic because the cable lengths are typically longer than<br />

the 100-meter limit for Category 5e UTP cable.<br />

Complete Figure 5-1 by filling in all the missing text labeling the components of this multibuilding<br />

campus LAN.