5.- INSTALLATION<br />

5.1 - CB70 (BC70K) BATTERY CHARGER<br />

The battery charger CB70 has two charging compartments that can simultaneously charge<br />

battery types BT06, BT12 (TM60 series) and BT06K, BT20K (TM70 series).<br />

Connect the charger to the mains using the power<br />

source and cable supplied. On installing the battery<br />

charger, bear in mind that the batteries must be charged<br />

at temperatures over 0ºC and that the power supply must<br />

be left on all night.<br />

Place the batteries in the charger. Please wait about 5<br />

seconds between consecutive insertions of batteries in<br />

their locations.<br />

Each battery location has a green led indicator<br />

associated.<br />

Green led indications:<br />

1) Green led blinking: it indicates that the battery is excessively unloa<strong>de</strong>d ; when the led finishes<br />

blinking it indicates that the normal loading operation mo<strong>de</strong> has begun.<br />

2) Green led permanently lightning: it indicates normal loading operation mo<strong>de</strong>.<br />

3) Green led extinguished: it indicates that the battery loading process has finished.<br />

The capacity of the batteries <strong>de</strong>creases with use. Their life span is estimated to be 500<br />

recharging cycles, but this <strong>de</strong>pends largely on the conditions of use, for which the following is<br />

recommen<strong>de</strong>d:<br />

Do not recharge the battery until it is completely flat. The transmitter indicates this moment.<br />

Always charge the batteries at temperatures between 0º and 45ºC (the batteries will not<br />

become fully charged at temperatures exceeding 45ºC). Remember that the charger must<br />

not be left in direct sunlight.<br />

Charge the batteries at least once every six months.<br />

Avoid short-circuits between the battery contacts. Do not carry charged batteries in<br />

toolboxes or next to other metal objects (keys, coins, etc.).<br />

Always keep contacts clean.<br />

Never leave batteries in direct sunlight.<br />

Warning: if the battery charger is powered with lower voltage than 10,3v DC, the green led<br />

indicates battery in charging process, even if there is no battery placed in the charger.<br />

TM70Pi V3.2 (11/02) 120021.pdf. 5<br />

IKUSI reserves the right to change this information without prior notice.<br />

CB70<br />

Only use IKUSI manufactured batteries<br />

The exhausted batteries must be disposed of or recycled safely according to local standards<br />

The IKUSI - ATEX batteries (BT06K-ATEX and BT20K-ATEX), only can be re-charged with the<br />

BC70K or CB70 battery charger. Remark: these batteries will damage when using IKUSI’s CB60<br />

battery charger.