TM70 – ANALOGUE FEEDBACK CALIBRATION<br />
14.1 - INTRODUCTION<br />
Systems with analogue feedback need to have the options Display and Analogue Feedback.<br />
Systems with analogue feedback need at startup the calibration of the analogue input by the<br />
distributor or the user. The following steps need to be done:<br />
14.2 - CALIBRATION OF THE ANALOGUE FEEDBACK WITH LCD DISPLAY<br />
Transmitters with display option, allow the operator the calibration of the analogue input through the<br />
edition of a three digit value plus a comma and a measurement unit up to three characters.<br />
The modified feedback calibration data will not be updated in the receiver<br />
EEPROM. In or<strong>de</strong>r to do it, please copy the new information located in the<br />
transmitter EEPROM into the receiver one.<br />
At the remote control start up the Calibration must be done as follows:<br />
1. Insert a fully charged battery and turn ON the<br />
contact key.<br />
2. Push and Pull the STOP pushbutton. An orange<br />
blink will be seen on the LED followed by green<br />
pulses and the LED switches off.<br />
3. Place a known load on the crane in or<strong>de</strong>r to<br />
introduce the First value in Calibration mo<strong>de</strong>.<br />
4. Switch off the remote control and start the system<br />
entering in CALIBRATION mo<strong>de</strong>. In or<strong>de</strong>r to do so,<br />
it is necessary to do the following:<br />
5. Press LCD70 push button ―ENTER‖ (<strong>de</strong>fault value)<br />
and press START pushbutton. Keep both<br />
pushbuttons pushed for a couple of seconds until<br />
the CONFIG option appears on the display.<br />
Remark: It is possible using the TMConfig<br />
tool to assign a different function; this<br />
function must <strong>de</strong>fined and written in the<br />
equipment technical datasheet<br />
6. Press the push button ―ENTER‖ to go into<br />
the MENU.<br />
7. To move through the menu, use ―UP‖ (▲) and ―DOWN‖ (▼) functions the CALIBRATION<br />
menu appears.<br />
TM70Pi V3.2 (11/02) 120021.pdf. 60<br />
IKUSI reserves the right to change this information without prior notice.