manual de instalação e utilização transmissor console ... - Usicontrol
manual de instalação e utilização transmissor console ... - Usicontrol
manual de instalação e utilização transmissor console ... - Usicontrol
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
7.3 - TROUBLESHOOTING<br />
The transmitter and receiver have status monitoring LED‘s, which help to i<strong>de</strong>ntify irregularities.<br />
The most common signals are contained in the tables below:<br />
TRANSMITTER<br />
LED MEANS<br />
Solid green Transmitter transmitting normally. OPERATION mo<strong>de</strong>.<br />
Green pulses. Transmitter ready for start-up. STAND BY mo<strong>de</strong>.<br />
Red slow flashing Battery level low<br />
Red fast flashing Probably, EEPROM module is not plugged in.<br />
Red double flashing Transmitter cannot start up because a manoeuvre command is<br />
present.<br />
Solid red Transmitter failure<br />
RECEIVER<br />
In OPERATION mo<strong>de</strong> the 5 LED‘s must be lit as has been previously <strong>de</strong>scribed in section 4.3<br />
Starting. If this is so, press the transmitter manoeuvre buttons and observe the response of the<br />
output relays. If the response is normal, the problem is not related to the remote control<br />
equipment and the installation must be checked. If any of the relays is not activated, the<br />
problem is associated with the remote control equipment. If this happens, observe the<br />
appearance of the LED‘s:<br />
LED LIT FLASHING OFF<br />
POWER Power Supply OK -- Power Supply not OK<br />
HARDOK Board OK<br />
Slow: fault in the board<br />
Fast: error in EEPROM<br />
SIGNAL RF signal OK RF signal <strong>de</strong>tection in<br />
SCANNING mo<strong>de</strong><br />
DATA -- Is receiving the correct data<br />
from a TM70<br />
Fault in the board<br />
The receiver is not receiving<br />
RF signals<br />
Signal received is not<br />
correct<br />
ID -- ID Co<strong>de</strong> OK ID not recognised<br />
ORDER<br />
Any digital<br />
manoeuvre ON<br />
TM70Pi V3.2 (11/02) 120021.pdf. 12<br />
IKUSI reserves the right to change this information without prior notice.<br />
--<br />
No digital manoeuvre ON<br />
RELAY STOP relays ON -- STOP relays OFF