11.1.1 - SYSTEM DESCRIPTION<br />

TM70 radio remote control systems can be equipped with a range limitation option for overhead<br />

cranes, through which, the system is able to <strong>de</strong>termine if the transmitter is located outsi<strong>de</strong> of a zone,<br />

<strong>de</strong>fined as a working area, and <strong>de</strong>activates the controls when these situations arise.<br />

The system consists of one or more Infrared transmitters LA70, installed either in fixed positions or on<br />

the controlled crane, oriented in such a way that it covers the targeted working zone. In these cases<br />

the transmitters of the remote control sets are equipped with a sensor which receives the information<br />

coming from the LA70 transmitter. This information is analysed by transmitter microprocessor, which,<br />

in this way knows when the operator has left the working area. Consequently, outputs are <strong>de</strong>activated.<br />

Application examples:<br />

11.1.2 - INFRARED SENSOR<br />

LA70<br />

As explained in the above, the sensor element is located in the remote control transmitter and its<br />

function is to receive the infrared information coming from the LA70 transmitter. The location of this<br />

sensor is the following:<br />

The transmitter microprocessor receives the information from the sensor and checks the i<strong>de</strong>ntity of the<br />

crane. As soon as the sensor stops receiving the signal coming from the crane, the transmitter LED,<br />

which was green, begins to flash in red, (in case of belly box transmitters, a buzzer also sounds), in<br />

or<strong>de</strong>r to let the operator know that he has moved too far away. If this situation lasts longer than 4<br />

seconds, all the active commands are cancelled, although communication is maintained with the<br />

receiver. In this way the main contactor and the selection or<strong>de</strong>rs are maintained.<br />

TM70Pi V3.2 (11/02) 120021.pdf. 43<br />