9.5.2 AVAILABLE ICONS:<br />
The available icons for the display are:<br />
- Battery: 43h direction. This icon is composed by other 4 icons<br />
o Cover of the battery<br />
o Left cell<br />
o Central cell<br />
o Right cell<br />
- NEW: 2h direction. If the level is different from zero, will appear<br />
9.5.3 DISPLAY CONTROL BY VT100<br />
CONTROL CHARACTERS<br />
The VT100 control characters recognized by the LCD70 display are:<br />
- ESC (1Bh): Control character that initialises a control sequence.<br />
- NUL (00h): Ignored on input (not stored in input buffer).<br />
All the other control characters cause no action to be taken.<br />
VALID CONTROL SEQUENCES<br />
Definitions:<br />
The following listing <strong>de</strong>fines the basic elements of the ANSI mo<strong>de</strong> control sequences.<br />
1. Control Sequence Introducer (CSI): in the VT100 the CSI is ESC [<br />
2. Parameter string: a string of parameters separated by a semicolon (3Bh)<br />
3. Final character: a character whose bit combination terminates an escape or control<br />
sequence („m‟, 6Dh)<br />
Control Sequences<br />
- ESC [ 0 (1Bh 5Bh 30h): Control sequence to turn off all character attributes (‗0‘ is the<br />
optional, <strong>de</strong>fault value)<br />
- ESC [Pn ; Pn H (1Bh 5Bh line 3Bh column 48h): moves the active position of the cursor to<br />
the position specified by the parameters. The <strong>de</strong>fault condition with no parameters present<br />
is equivalent to a cursor to home action. Lines are numbered consecutively, with the origin<br />
being line 1, column 1. The cursor is not allowed to be positioned outsi<strong>de</strong> the margins<br />
(lines 1 to 4, columns 1 to 12). A sequence with one Pn numeric parameter with a <strong>de</strong>fault<br />
(0) parameter will be interpreted as wrong sequence. Example: ESC [ 2 ; 0 H or ESC [ 2 ;<br />
H are wrong sequences !<br />
- ESC [ 2 J (1Bh 5Bh 32h 4Ah): all lines are erased, and the cursor does not move<br />
- ESC [ 4 (1Bh 5Bh 34h): All following characters transmitted are un<strong>de</strong>rscored until receiving<br />
an escape sequence ESC [ 0 m<br />
- ESC [ 5 (1Bh 5Bh 35h): All following characters transmitted are blink until receiving an<br />
escape sequence ESC [ 0 m<br />
- ESC [ 7 1Bh 5Bh 37h): All following characters transmitted are negative (reverse) image until<br />
receiving an escape sequence ESC [ 0 m<br />
TM70Pi V3.2 (11/02) 120021.pdf. 35<br />
IKUSI reserves the right to change this information without prior notice.