Product Configuration/Specifications: 10,000 OPM Orbital Sander<br />
Product Configuration and Specifications: 10,000 OPM 75 <strong>mm</strong> x 100 <strong>mm</strong> (3 in. x 4 in.) Orbital Sander – 3 <strong>mm</strong> (1/8 in.) Orbit<br />
Note: All Self Generated Vacuum machines use Ø 28 <strong>mm</strong> (1 in.) Vacuum Hose Fittings Standard. Ø 19 <strong>mm</strong> (3/4 in.) is available.<br />
All Central Vacuum machines use Ø 19 <strong>mm</strong> (3/4 in.) Vacuum Hose Fittings Standard. Ø 28 <strong>mm</strong> (1 in.) is available.<br />
Orbit Vac<br />
Type<br />
3 <strong>mm</strong><br />
(1/8 in,)<br />
Central<br />
Vacuum<br />
Self-Gen<br />
Vacuum<br />
Pad Size<br />
<strong>mm</strong> (in,)<br />
75 x 100<br />
(3 x 4)<br />
75 x 100<br />
(3 x 4 )<br />
Non-vac 75 x 100<br />
(3 x 4 )<br />
Model<br />
Number<br />
Product Net<br />
Weight kg<br />
(Pounds)<br />
Specifications subject to change without prior notice.<br />
Height<br />
<strong>mm</strong><br />
(inch)<br />
<strong>OS</strong>343CV 0,72 (1,58) 83,5<br />
(3,29)<br />
<strong>OS</strong>343DB 0,72 (1,58) 83,5<br />
(3,29)<br />
<strong>OS</strong>343NV 0,70 (1,55) 83,5<br />
(3,29)<br />
Length<br />
<strong>mm</strong><br />
(inch)<br />
202,4<br />
(8,0)<br />
208,9<br />
(8,2)<br />
139,3<br />
(5,5)<br />
*The values stated in the table are from laboratory testing in conformity with stated codes and standards and are not sufficient for<br />
risk evaluation. Values measured in a particular work place may be higher than the declared values. The actual exposure values<br />
and amount of risk or harm experienced to an individual is unique to each situation and depends upon the surrounding environment,<br />
the way in which the individual works, the particular material being worked, work station design as well as upon the exposure<br />
time and the physical condition of the user. <strong>KWH</strong> <strong>Mirka</strong>, <strong>Ltd</strong>. cannot be held responsible for the consequences of using declared<br />
values instead of actual exposure values for any individual risk assessment.<br />
Further occupational health and safety information can be obtained from the following websites:<br />
http://europe.osha.eu.int (Europe)<br />
http://www.osha.gov (USA)<br />
6<br />
Power<br />
watts<br />
(HP)<br />
179<br />
(0,24)<br />
179<br />
(0,24)<br />
179<br />
(0,24)<br />
Air Consumption<br />
LPM (scfm)<br />
*Noise<br />
Level<br />
dBA<br />
*Vibration<br />
Level<br />
m/s 2<br />
*Uncertainty<br />
K<br />
m/s 2<br />
453 (16) 76 2,6 1,3<br />
453 (16) 81 3,5 1,7<br />
453 (16) 76 2,6 1,3<br />
The noise test is carried out in accordance with EN ISO 15744:2008 - Hand-held non-electric power tools - Noise measurement code - Engineering method<br />
(grade 2).<br />
The vibration test is carried out in accordance with EN 28662-1. Hand-held portable power tools – Measurement of vibration at the handle. Part 1: General and<br />
EN 8662-8, 1997. Hand-held portable power tools – Measurement of vibration at the handle. Part 8: Polishers and rotary, orbital and random orbital sanders.