hp<strong>iLO</strong>-> show<br />
For example:<br />
/system1/fan1<br />
Targets<br />
Properties<br />
DeviceID=Fan 1<br />
ElementName=System<br />
OperationalStatus=Ok<br />
VariableSpeed=Yes<br />
DesiredSpeed=14 percent<br />
HealthState=Ok<br />
VRM power supplies are usually mapped to the sensor targets. The following comm<strong>and</strong> displays<br />
the VRM 1 properties:<br />
show system1/sensor1<br />
For example:<br />
/system1/sensor1<br />
Targets<br />
Properties<br />
DeviceID=VRM 1<br />
ElementName=CPU 1<br />
OperationalStatus=Ok<br />
RateUnits=Volts<br />
CurrentReading=0<br />
SensorType=Voltage<br />
HealthState=Ok<br />
oemhp_CautionValue=0<br />
oemhp_CriticalValue=0<br />
When VRM power supplies are not mapped to sensor targets, the following comm<strong>and</strong> displays<br />
power supply properties:<br />
hp<strong>iLO</strong>-> show<br />
For example:<br />
/system1/powersupply1<br />
Targets<br />
Properties<br />
ElementName=Power Supply<br />
OperationalStatus=Ok<br />
HealthState=Ok<br />
Other sensor targets show system temperatures. The following comm<strong>and</strong> displays one of the<br />
temperature zone properties:<br />
hp<strong>iLO</strong>-> show<br />
For example:<br />
/system1/sensor1<br />
Targets<br />
Properties<br />
DeviceID=Temp 1<br />
ElementName=Ambient<br />
OperationalStatus=Ok<br />
RateUnits=Celsius<br />
CurrentReading=20<br />
SensorType=Temperature<br />
HealthState=Ok<br />
42 SMASH CLP <strong>Scripting</strong> Language