22.03.2013 Views

Enabler-G AT Command Set - SE Spezial-Electronic AG

Enabler-G AT Command Set - SE Spezial-Electronic AG

Enabler-G AT Command Set - SE Spezial-Electronic AG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>AT</strong> <strong>Command</strong> <strong>Set</strong> Reference<br />

Version 1.08<br />

2.4.4.11. <strong>AT</strong>+CACM Accumulated Call Meter<br />

<strong>Command</strong> Function <strong>Set</strong> command resets the Advice of Charge<br />

related accumulated call meter value in SIM<br />

file EFACM. ACM contains the total number<br />

of home units for both the current and<br />

preceding calls. SIM PIN2 is usually<br />

required to reset the value.<br />

<strong>Command</strong> Functional Phone Control<br />

Group<br />

<strong>Command</strong> Format Query N/A<br />

Response N/A<br />

Write Format N/A<br />

Response N/A<br />

Read Format <strong>AT</strong>+CACM?<br />

Response +CACM: “000000”<br />

OK<br />

Execution Format <strong>AT</strong>+CACM=<br />

Response OK<br />

Parameter Values : string type; SIM PIN2<br />

Reference GSM Ref. 07.07 Chapter 8.25<br />

Standard Scope Optional<br />

Enfora Implementation Scope Full<br />

Notes Used in conjunction with <strong>AT</strong>+CAOC and<br />

<strong>AT</strong>+CAMM<br />

Example:<br />

<strong>AT</strong>+CACM=”1234”<br />

Password<br />

GSM0107PB001MAN Page 101 of 370 1.08 – 25 January 2007