<strong>AT</strong> <strong>Command</strong> <strong>Set</strong> Reference<br />

Version 1.08<br />

3.2.8.7. $PADTO PAD Timeout Value<br />

<strong>Command</strong> Function This command allows the user to query/set<br />

the PAD timeout value. Data will be<br />

forwarded to the PAD destination even if<br />

the PAD block size has not been reached if<br />

period has elapsed since the<br />

last PAD character was received from the<br />

local host.<br />

<strong>Command</strong> Functional Enfora Specific<br />

Group<br />

<strong>Command</strong> Format Query <strong>AT</strong>$PADTO<br />

Response $PADTO: (0-65535)<br />

OK<br />

Write Format <strong>AT</strong>$PADTO = <br />

Response OK<br />

Read Format <strong>AT</strong>$PADTO<br />

Response $PADTO: <br />

Execution Format N/A<br />

Response N/A<br />

Parameter Values<br />

The number of tenths of seconds to wait for<br />

the receipt of more PAD data before<br />

forwarding the currently accumulated PAD<br />

buffer to the PAD destination. A value of<br />

zero disables the PAD timeout feature. If<br />

the PAD timeout feature is disabled, no<br />

data will be forwarded to the destination<br />

until either an enabled forward character is<br />

received, or the selected PAD buffer size is<br />

reached. (50 = 5 seconds)<br />

Reference N/A<br />

Standard Scope Optional<br />

Enfora Implementation Scope Full<br />

Notes N/A<br />