22.03.2013 Views

Enabler-G AT Command Set - SE Spezial-Electronic AG

Enabler-G AT Command Set - SE Spezial-Electronic AG

Enabler-G AT Command Set - SE Spezial-Electronic AG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>AT</strong> <strong>Command</strong> <strong>Set</strong> Reference<br />

Version 1.08<br />

3.2.4.4. $IOADCx Read Analog to Digital Converter<br />

<strong>Command</strong> Function: This command returns the value of the last<br />

reading on the Analog to Digital Converter<br />

in millivolts.<br />

<strong>Command</strong> Functional<br />

Group Enfora Specific<br />

<strong>Command</strong> Format Query N/A<br />

Response N/A<br />

Write Format N/A<br />

Response N/A<br />

Read Format N/A<br />

Response N/A<br />

Execution Format <strong>AT</strong>$IOADCx<br />

Response $IOADCx: <br />

OK<br />

Parameter Values<br />

x 1 Value of ADC1<br />

2 Value of ADC2<br />

decimal value in millivolts<br />

Reference N/A<br />

Standard Scope Optional<br />

Enfora Implementation Scope Full<br />

Notes See applicable Integration Guide for pinout<br />

definitions. If the modem is not registered<br />

or attached, the modem may take up to a<br />

minute to update the digital output to reflect<br />

a change on the analog input. 0 – 1.75 Vdc<br />

range. 1.709 mV resolution. 10 bit.<br />

GSM0107PB001MAN Page 226 of 370 1.08 – 25 January 2007