<strong>AT</strong> <strong>Command</strong> <strong>Set</strong> Reference<br />

Version 1.08<br />

3.2.8.8. $PADCMD PAD <strong>Command</strong> Features<br />

<strong>Command</strong> Function This command allows the user to set/query<br />

PAD configuration options.<br />

<strong>Command</strong> Functional Enfora Specific<br />

Group<br />

<strong>Command</strong> Format Query <strong>AT</strong>$PADCMD=?<br />

Response $PADCMD: (00-1B)<br />

OK<br />

Write Format <strong>AT</strong>$PADCMD =<br />

Response OK<br />

Read Format <strong>AT</strong>$PADCMD?<br />

Response $PADCMD: "”<br />

Execution Format N/A<br />

Response N/A<br />

Parameter Values<br />

AND selected HEX options into a single<br />

16 bit word.<br />

01=Enable forwarding on special char<br />

02=Forward special char with data<br />

08=Enable backspace<br />

Reference N/A<br />

Standard Scope Optional<br />

Enfora Implementation Scope Full<br />

Notes A +++ is an escape sequence to exit PAD<br />

mode. Disabling of the escape sequence is<br />

not supported, however the escape is only<br />

applicable when there is a 1 second guard<br />

time before and after the +++. If the guard<br />

period is not met before and after the<br />

escape sequence, it will be forwarded as<br />

data.<br />

GSM0107PB001MAN Page 256 of 370 1.08 – 25 January 2007