<strong>AT</strong> <strong>Command</strong> <strong>Set</strong> Reference<br />

Version 1.08<br />

3.2.9.2. $EVTIM# User Defined Input Event Timers<br />

<strong>Command</strong> Function This command allows the user to define up<br />

to 4 separate periodic input events in 1<br />

second increments<br />

<strong>Command</strong> Functional Enfora Specific<br />

Group<br />

<strong>Command</strong> Format Query <strong>AT</strong>$EVTIM#=?<br />

Response $EVTIM#: (0-604800)<br />

GSM0107PB001MAN Page 274 of 370 1.08 – 25 January 2007<br />

OK<br />

Write Format <strong>AT</strong>$EVTIM#=<br />

Response OK<br />

Read Format <strong>AT</strong>$EVTIM#?<br />

Response $EVTIM#: <br />

Execution Format N/A<br />

Response N/A<br />

Parameter Values<br />

number of seconds between each<br />

generated input event.<br />

Reference N/A<br />

Standard Scope Optional<br />

Enfora Implementation Scope Full<br />

Notes <strong>AT</strong>$EVTIM4 will affect the values in<br />

<strong>AT</strong>$WAKEUP. Do not use this event timer<br />

if you are using <strong>AT</strong>$WAKEUP.