<strong>AT</strong> <strong>Command</strong> <strong>Set</strong> Reference<br />

Version 1.08<br />

2.6.1.21. <strong>AT</strong>+ICF TE-TA Character Framing<br />

<strong>Command</strong> Function This command determines the number of<br />

data/stop/parity bits that will be used by the<br />

TA serial interface.<br />

<strong>Command</strong> Functional State Control<br />

Group<br />

<strong>Command</strong> Format Query <strong>AT</strong>+ICF=?<br />

Response +ICF: (1-6), (0-3)<br />

OK<br />

Write Format <strong>AT</strong>+ICF=,<br />

Response OK<br />

Read Format <strong>AT</strong>+ICF?<br />

Response +ICF: 3<br />

OK<br />

Execution Format N/A<br />

Response N/A<br />

Parameter Values<br />

1 8 data, 2 stop, no parity<br />

2 8 data, 1 stop,1 parity<br />

3 8 data, 1 stop, no parity<br />

4 7 data, 2 stop, no parity<br />

5 7 data, 1 stop, 1 parity<br />

6 7 data, 1 stop, no parity<br />

0 odd<br />

1 even<br />

2 mark<br />

3 space<br />

Reference GSM Ref. 07.0 Chapter 6.2.11<br />

Standard Scope Mandatory<br />

Enfora Implementation Scope Partial<br />

Notes If no parity is specified in , then<br />

is ignored.<br />

GSM0107PB001MAN Page 163 of 370 1.08 – 25 January 2007