<strong>AT</strong> <strong>Command</strong> <strong>Set</strong> Reference<br />

Version 1.08<br />

3.2.11.34. $OFFDLY Power off delay<br />

<strong>Command</strong> Function This command allows the user to configure<br />

the minimum time that the PWR_CTRL<br />

signal must be low before the module<br />

recognizes the signal as a power off<br />

command. This delay can be considered<br />

as a software debounce time for the<br />

PWR_CTRL signal.<br />

<strong>Command</strong> Functional Enfora Specific<br />

Group<br />

If the PWR_CTRL signal is held low for<br />

longer than the time specified by $OFFDLY,<br />

then the modem performs a softwarecontrolled<br />

shutdown. The modem<br />

gracefully deregisters from the network<br />

before powering down so it may take a few<br />

seconds before current consumption<br />

decreases. Requires a pulse on the<br />

PWR_CTRL or RE<strong>SE</strong>T pin to wake the unit<br />

back up.<br />

<strong>Command</strong> Format Query <strong>AT</strong>$OFFDLY=?<br />

Response $OFFDLY: (0,100-250 msec)<br />

OK<br />

Write Format <strong>AT</strong>$OFFDLY=<br />

Response OK<br />

Read Format <strong>AT</strong>$OFFDLY?<br />

Response $OFFDLY: <br />

Execution Format N/A<br />

Response N/A<br />