Railway Group Approved Code of Practice<br />

GK/RC0752<br />

Issue Two<br />

Date December 1998<br />

Page E38 of 52<br />

Withdrawn Document<br />

Unc<strong>on</strong>trolled When Printed<br />

<str<strong>on</strong>g>General</str<strong>on</strong>g> <str<strong>on</strong>g>Informati<strong>on</strong></str<strong>on</strong>g> <strong>on</strong> <strong>Track</strong> <strong>Circuits</strong><br />

17.2 Impedance B<strong>on</strong>d Lug Plates<br />

In the case of the Style P3 impedance b<strong>on</strong>d, the busbar is not secured directly to<br />

the impedance b<strong>on</strong>d lug plate as with all other impedance b<strong>on</strong>d types. A<br />

separate lug plate (Railway Catalogue No. 88/27761) is required, as shown in<br />

Figure E44. This is secured to the impedance b<strong>on</strong>d lugs with four 1¼” x 3 /8”<br />

hexag<strong>on</strong> headed BSW bolts, plain spring washers and nuts, which are provided<br />

with the impedance b<strong>on</strong>d.<br />

17.3 Packing Pieces<br />

The arrangement of packing pieces required between busbar and sleeper is<br />

shown in Figure E29. The packing pieces are illustrated in Figure E45. They are<br />

not attached to the sleepers but secured to the busbar using No.10 x 1¼” wood<br />

screws.<br />

17.4 Busbar Restrictor<br />

The busbar is maintained in positi<strong>on</strong> by a busbar restrictor arrangement. This<br />

comprises a pair of side stops (Railway Catalogue No 88/27760) as shown in<br />

Figure E46. The side stops incorporate a steel rod assembly to prevent<br />

excessive vertical movement. Installati<strong>on</strong> of the busbar restrictor is shown in<br />

Figure E43.<br />

17.5 Impedance B<strong>on</strong>d C<strong>on</strong>necti<strong>on</strong> Arrangements<br />

Figure E37 shows the various c<strong>on</strong>necti<strong>on</strong> arrangements to be applied to Type 3 impedance b<strong>on</strong>ds installed in new<br />

works. C<strong>on</strong>necti<strong>on</strong>s for maintenance replacement of other types of impedance b<strong>on</strong>d are shown in Figure 38.<br />

E 38 R A I L T R A C K