General Information on Track Circuits - RGS Online
General Information on Track Circuits - RGS Online
General Information on Track Circuits - RGS Online
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<str<strong>on</strong>g>General</str<strong>on</strong>g> <str<strong>on</strong>g>Informati<strong>on</strong></str<strong>on</strong>g> <strong>on</strong> <strong>Track</strong> <strong>Circuits</strong><br />
B<strong>on</strong>d Not Secured To<br />
sleeper At This End<br />
For Cable Lengths<br />
See Secti<strong>on</strong> E18<br />
S S<br />
Plastic Pipe<br />
Type 2 B<strong>on</strong>d<br />
Withdrawn Document<br />
Unc<strong>on</strong>trolled When Printed<br />
Railway Group Approved Code of Practice<br />
GK/RC0752<br />
Issue Two<br />
Date December 1998<br />
Page E33 of 52<br />
16.2 Type 2 Impedance B<strong>on</strong>d<br />
The standard installati<strong>on</strong> arrangements for Type 2 (Style MR or S) impedance<br />
b<strong>on</strong>ds <strong>on</strong> c<strong>on</strong>crete or wooden sleepers are shown in Figure E28 and Figure<br />
E29.<br />
Arrangement This Side of IRJ To Be Used<br />
For Double/Single & Double/Double Layout For<br />
Type 2 B<strong>on</strong>d<br />
For Rail C<strong>on</strong>necti<strong>on</strong>s<br />
see Secti<strong>on</strong> E8<br />
For Busbar Packing<br />
see Secti<strong>on</strong> E17<br />
This Drawing Should Only Be Used For<br />
Renewal of Individual Comp<strong>on</strong>ents in<br />
Existing Installati<strong>on</strong>s<br />
I.R.J.<br />
For Busbar Details<br />
See Secti<strong>on</strong> E17<br />
Notes<br />
All Cables To Be Clear<br />
of Tamping<br />
Z<strong>on</strong>es see Secti<strong>on</strong> E6<br />
R A I L T R A C K E 33<br />
I.R.J.<br />
Arrangements This Side of IRJ To Be Used<br />
For Double/Single Layouts<br />
S S<br />
For Busbar Restrictor<br />
Arrangement<br />
see Figure E43<br />
Hole Positi<strong>on</strong>s In Busbar<br />
To Be Drilled On Site<br />
For securing b<strong>on</strong>d <strong>on</strong> c<strong>on</strong>crete sleepers drill <strong>on</strong> centre line at 400 ctrs 12 dia and secure with Hilti heavy duty<br />
anchors HSA 12x 110 Hilti code 66337 (2 OFF). For wooden sleepers use coach screws 5/8" x 6".<br />
Catalogue No 35/13950. Screws not to be driven fully home but left approximately 25 above b<strong>on</strong>d lugs.<br />
Figure E29