Railway Group Approved Code of Practice<br />

GK/RC0752<br />

Issue Two<br />

Date December 1998<br />

Page E30 of 52<br />

16 Impedance B<strong>on</strong>d<br />

Installati<strong>on</strong><br />

Withdrawn Document<br />

Unc<strong>on</strong>trolled When Printed<br />

<str<strong>on</strong>g>General</str<strong>on</strong>g> <str<strong>on</strong>g>Informati<strong>on</strong></str<strong>on</strong>g> <strong>on</strong> <strong>Track</strong> <strong>Circuits</strong><br />

15.5.7 Style M2/5<br />

Descripti<strong>on</strong> Catalogue No<br />

Coil, c<strong>on</strong>denser : 88/26065<br />

Plate, lug, steel (pairs with screws)<br />

for fitting side c<strong>on</strong>necti<strong>on</strong>s : 88/83987<br />

15.5.8 Style M6<br />

Obsolete, parts out of producti<strong>on</strong>.<br />

15.5.9 Style DD<br />

Descripti<strong>on</strong> Catalogue No<br />

Coil, auxiliary : 88/83553<br />

Gasket, main cover : 88/27047<br />

15.5.10 Style B<br />

Descripti<strong>on</strong> Catalogue No<br />

Coil auxiliary : 88/83958<br />

Terminal box : 88/25802<br />

Cover, terminal box : 88/83959<br />

15.5.11 <str<strong>on</strong>g>General</str<strong>on</strong>g> Spares<br />

Descripti<strong>on</strong> Catalogue No<br />

Sealing Compound Red Hermabte no. 5400 : 7/60180<br />

Oil, insulating (impedance b<strong>on</strong>ds) 2.5 litre : 27/13802<br />

CAUTION: Care should be taken to avoid trapping fingers when handling<br />

impedance b<strong>on</strong>ds.<br />

16.1 Type 3 Impedance B<strong>on</strong>d<br />

Type 3 impedance b<strong>on</strong>ds supplied to BR863 have blanking plates, grommets or<br />

plastic plugs in the terminal box holes, together with <strong>on</strong>e M25 gland, for 2c Type<br />

C2 2.5mm²(f) and four M20 glands, for single core Type C1 2. 5mm²(f).<br />

The impedance b<strong>on</strong>d is also supplied with resilient mountings, either fitted or<br />

supplied separately. The resilient mounting feet comprise two porti<strong>on</strong>s and, if<br />

not already fitted, should be glued together using Araldite Rapide or Araldite<br />

(Railway Catalogue No. 7/103330).<br />

The cable glands should be fitted as required and the internal lock nuts glued<br />

with Araldite. If unused holes are fitted with plastic plugs, these should be<br />

replaced with threaded blanking plates. Surplus blanking plates, grommets and<br />

glands should be retained as spares.<br />

In instances where the auxiliary coil box is pr<strong>on</strong>e to water accumulati<strong>on</strong>, a 3mm<br />

hole may be carefully drilled in the bottom of the terminal box and all swarf<br />

cleared away.<br />

The b<strong>on</strong>d is now ready for installati<strong>on</strong>.<br />

The standard installati<strong>on</strong> arrangements for Type 3 b<strong>on</strong>ds <strong>on</strong> c<strong>on</strong>crete or wooden<br />

sleepers (Howells or WBS Style WH3) are shown in Figure E26, Figure E27<br />

and Figure E28.<br />