Railway Group Approved Code of Practice<br />

GK/RC0752<br />

Issue Two<br />

Date December 1998<br />

Page E32 of 52<br />

Arrangement This<br />

Side of IRJ To Be Used<br />

For Double/Single &<br />

Double/Double<br />

Layout For Type 3 B<strong>on</strong>d<br />

Arrangement This<br />

Side of IRJ To Be Used<br />

For Double/Single &<br />

Double/Double<br />

Layout For Type 3 B<strong>on</strong>d<br />

I.R.J.<br />

I.R.J.<br />

<str<strong>on</strong>g>General</str<strong>on</strong>g> <str<strong>on</strong>g>Informati<strong>on</strong></str<strong>on</strong>g> <strong>on</strong> <strong>Track</strong> <strong>Circuits</strong><br />

Figure E27 shows the Busbar Pin Brazed C<strong>on</strong>necti<strong>on</strong>s for Plain Line/L<strong>on</strong>g<br />

Switch Fr<strong>on</strong>ts.<br />

For Busbar Details<br />

See Secti<strong>on</strong> E17<br />

For Busbar Packing<br />

See Secti<strong>on</strong> E17<br />

For Cable Lengths<br />

See Secti<strong>on</strong> E18<br />

Arrangements This Side of IRJ To Be Used For<br />

Double/Single Layouts<br />

Figure E27<br />

200<br />

200<br />

Hole Positi<strong>on</strong>s In Busbar<br />

To Be Drilled On Site<br />

For Rail C<strong>on</strong>necti<strong>on</strong>s see<br />

Secti<strong>on</strong> E8<br />

Notes<br />

All Cables To Be Clear of<br />

Tamping Z<strong>on</strong>es<br />

See Secti<strong>on</strong> E6<br />

E 32 R A I L T R A C K<br />

155<br />

240<br />

155<br />

240<br />

For Busbar Restrictor<br />

Arrangement<br />

See Figure E43<br />

200<br />

200<br />

For Rail C<strong>on</strong>necti<strong>on</strong>s see Secti<strong>on</strong> E8<br />

Figure E27 shows the Busbar Pin Brazed C<strong>on</strong>necti<strong>on</strong>s for Short Switch Fr<strong>on</strong>ts.<br />

I.R.J.<br />

For Busbar Details<br />

See Secti<strong>on</strong> E17<br />

For Busbar Packing<br />

See Secti<strong>on</strong> E17<br />

For Cable Lengths<br />

See Secti<strong>on</strong> E18<br />

I.R.J.<br />

Withdrawn Document<br />

Unc<strong>on</strong>trolled When Printed<br />

Arrangements This Side of IRJ To Be Used For<br />

Double/Single Layouts<br />

Notes<br />

All Cables To Be Clear of<br />

Tamping Z<strong>on</strong>es Secti<strong>on</strong> E6<br />

Figure E28<br />

S S<br />

For Rail C<strong>on</strong>necti<strong>on</strong>s see Secti<strong>on</strong> E8<br />

155<br />

240<br />

155<br />

240<br />

For Busbar Restrictor<br />

Arrangement<br />

See Figure E43<br />

Hole Positi<strong>on</strong>s In Busbar<br />

To Be Drilled On Site<br />

For Rail C<strong>on</strong>necti<strong>on</strong>s<br />

see Secti<strong>on</strong> E8