<str<strong>on</strong>g>General</str<strong>on</strong>g> <str<strong>on</strong>g>Informati<strong>on</strong></str<strong>on</strong>g> <strong>on</strong> <strong>Track</strong> <strong>Circuits</strong><br />

Notes<br />

*<br />

Intertrack Cables A<br />

* IRJ<br />

Intertrack CablesB<br />

2 For details of all busbars see Figure E39.<br />

Item 1<br />

DOUBLE RAIL TRACK CIRCUIT TO NO TRACK CIRCUITED LINES<br />

T.P. Huts Neg Return B<br />

Item 3<br />

IRJ<br />

Double Rail <strong>Track</strong> Circuit to Double Rail <strong>Track</strong> Circuit Substati<strong>on</strong>s<br />

4 Tracti<strong>on</strong> Return cable sizes : A = 240mm2 Aluminium B = 800mm2 Aluminium<br />

5 Where TI.21 <strong>Track</strong> <strong>Circuits</strong> rail b<strong>on</strong>ds require to share the first sleeper bay with the tracti<strong>on</strong> return cable,<br />

they must be taped to the tracti<strong>on</strong> return cable. Orange pipe must not be used<br />

IRJ<br />

IRJ<br />

T.P Hut Neg Return A Neg Reinforcing CableB<br />

* IRJ<br />

Intertrack Cables A<br />

Item 5<br />

IRJ<br />

Double Rail <strong>Track</strong> Circuit to Single Rail <strong>Track</strong> <strong>Circuits</strong><br />

T.P. Huts Or Cross B<strong>on</strong>ding Sites.<br />

1 All lugs complete with bolts, nuts and washers for negative cross b<strong>on</strong>ding substati<strong>on</strong>s and T.P. hut<br />

cable attached to busbar to be supplied and fitted by Electric Tracti<strong>on</strong> Engineer.<br />

3 For full details of layouts see Figure E26, Figure E27, Figure E28.<br />

6 The Electric Tracti<strong>on</strong> Engineers lugs to be attached to the top of the busbar (Figure E55 for marking jig).<br />

7 Impedance b<strong>on</strong>ds at substati<strong>on</strong>s and T.P. Huts to be sited in co-operati<strong>on</strong> with the Electric Tracti<strong>on</strong> Engineer.<br />

8 In all layouts a l<strong>on</strong>ger busbar may be provided where necessary to accommodate reinforcing cables.<br />

* Cross track orange plastic pipe for protecti<strong>on</strong> of signalling cables.<br />

*<br />

Withdrawn Document<br />

Unc<strong>on</strong>trolled When Printed<br />

*<br />

*<br />

Railway Group Approved Code of Practice<br />

GK/RC0752<br />

Issue Two<br />

Date December 1998<br />

Page E39 of 52<br />

* *<br />

Intertrack Cables A<br />

Substati<strong>on</strong> Neg ReturnB<br />

* IRJ<br />

Intertrack Cables B<br />

R A I L T R A C K E 39<br />

Item 4<br />

IRJ<br />

Double Rail <strong>Track</strong> Circuit to Single Rail <strong>Track</strong> <strong>Circuits</strong> Substati<strong>on</strong>s<br />

N.B. This Arrangement is Also Used at Sites Other Than Substati<strong>on</strong>s<br />

IRJ<br />

IRJ<br />

Item 2<br />

Double Rail <strong>Track</strong> Circuit to Double Rail <strong>Track</strong> Circuit<br />

Substati<strong>on</strong> Neg Returns<br />

Intertrack Cables B<br />

Item 6<br />

Double Rail <strong>Track</strong> Circuit Intermediate B<strong>on</strong>d<br />

At Substati<strong>on</strong><br />

T.P. Huts or Cross B<strong>on</strong>ding Sites<br />

B<br />

*<br />

*<br />

Neg Reinforcing Cable<br />

See Note 9<br />

B<br />

T.P. Hut<br />

B<br />

Neg Return<br />

Intertrack CablesA<br />

Item 7<br />

Double Rail <strong>Track</strong> Circuit Intermediate<br />

B<strong>on</strong>d T.P. Huts Or Cross B<strong>on</strong>ding Sites