<str<strong>on</strong>g>General</str<strong>on</strong>g> <str<strong>on</strong>g>Informati<strong>on</strong></str<strong>on</strong>g> <strong>on</strong> <strong>Track</strong> <strong>Circuits</strong><br />

15 Impedance B<strong>on</strong>ds<br />

Manufacturer Style Freq.<br />

(Hz)<br />

Howells or<br />

WBS<br />

Howells or<br />

WBS<br />

Railway Group Approved Code of Practice<br />

GK/RC0752<br />

Issue Two<br />

Date December 1998<br />

Page E25 of 52<br />

15.1 Handling Precauti<strong>on</strong>s<br />

When transporting impedance b<strong>on</strong>ds, they should be lifted <strong>on</strong>ly by the lifting lugs<br />

or at the defined lifting points. Under no circumstances should any weight be<br />

taken <strong>on</strong> the tracti<strong>on</strong> lead terminals or cable lugs as this can result in damage to<br />

the insulati<strong>on</strong>, allowing water to enter.<br />

Type 3 impedance b<strong>on</strong>ds have positi<strong>on</strong>s for lifting lugs to be fitted, which should<br />

be removed as so<strong>on</strong> as the impedance b<strong>on</strong>d has been placed in the track and<br />

replaced with the supplied means of protecting the threads.<br />

15.2 Impedance B<strong>on</strong>d Types and Restricti<strong>on</strong>s<br />

Refer to the table in Figure E22<br />

Functi<strong>on</strong> Type Cat No Oil<br />

Filled<br />

Aux. Coil<br />

Ratio<br />

Weight<br />

(Kg)<br />

Supply<br />

WH3 50 Universal 3 86/17024 No 56: 1 160 N<br />

MR or<br />

S<br />

50 Universal 2 86/17023 No 56:1 160 O<br />

WBS P3 50 Universal 1 88/1237 Yes 45:1 S<br />

SGE DE 50 Universal I 88/83945 Yes 40:1 120 S<br />

WBS M 50/75 Specific 0 Yes 42:1 230 O<br />

WBS M2/5 50/75 Specific* 0 88/83948 Yes 42:1 190 S<br />

WBS M650/<br />

75<br />

Withdrawn Document<br />

Unc<strong>on</strong>trolled When Printed<br />

Specific 0 88/83952 Yes 45:1 230 O<br />

SGE DD 50 Universal 0 Yes 42:1 230 O<br />

GRS B 50 Specific 0 Yes 45:1 O<br />

Figure E22<br />

The table in Figure E22 is interpreted as follows:<br />

Functi<strong>on</strong><br />

Universal<br />

Impedance b<strong>on</strong>ds shown as ”Universal” may be used for all functi<strong>on</strong>s in all<br />

styles of track circuit approved for use in d.c. electric tracti<strong>on</strong> areas,<br />

subject <strong>on</strong>ly to their ability to cope with the designed tracti<strong>on</strong> current load.<br />

Note: Saturati<strong>on</strong> levels and avoidance of particular combinati<strong>on</strong>s of b<strong>on</strong>d<br />

and track relay, should be c<strong>on</strong>sidered when replacing b<strong>on</strong>ds of <strong>on</strong>e style<br />

with another (see Clause 15.4).<br />

The impedance b<strong>on</strong>ds are tuned to 50Hz. For other frequencies, internal<br />

res<strong>on</strong>ating capacitors are fitted.<br />

Specific<br />

Impedance b<strong>on</strong>ds shown as ”Specific” are specially set or tuned to perform<br />

feed, relay or intermediate functi<strong>on</strong>s at a particular frequency. If, in an<br />

emergency, an impedance b<strong>on</strong>d is required to perform a different functi<strong>on</strong><br />

or operate at the other frequency, it should be re–tuned.<br />

R A I L T R A C K E 25