<str<strong>on</strong>g>General</str<strong>on</strong>g> <str<strong>on</strong>g>Informati<strong>on</strong></str<strong>on</strong>g> <strong>on</strong> <strong>Track</strong> <strong>Circuits</strong><br />

1 Introducti<strong>on</strong><br />

2 High Voltages<br />

3 Lineside Apparatus<br />

Housing Inspecti<strong>on</strong><br />

4 B<strong>on</strong>ding Inspecti<strong>on</strong><br />

Withdrawn Document<br />

Unc<strong>on</strong>trolled When Printed<br />

Part G<br />

Testing and Commissi<strong>on</strong>ing<br />

Railway Group Approved Code of Practice<br />

GK/RC0752<br />

Issue Two<br />

Date December 1998<br />

Page G1 of 3<br />

The requirements for testing and commissi<strong>on</strong>ing of track circuits are detailed in<br />

the following:<br />

New Works : GK/RH 0730<br />

Maintenance/Fault Finding : GK/RH 0740<br />

Details of available instrumentati<strong>on</strong> and its uses are given in Part F.<br />

This Part details the general requirements for testing and commissi<strong>on</strong>ing.<br />

Reference should also be made to the Testing & Commissi<strong>on</strong>ing Part of the<br />

Code of Practice for the particular track circuit design involved.<br />

Ensure that warning signs (Figure E21) are fixed to all exposed track circuit<br />

capacitors and to the outside of lineside apparatus housings c<strong>on</strong>taining high<br />

voltage track circuit equipment.<br />

Details of the warning signs can be found in Part E.<br />

Check that:<br />

a) All track equipment is of the correct type, as specified in the wiring diagrams,<br />

and that applicable pin code c<strong>on</strong>figurati<strong>on</strong>s are correct.<br />

b) All equipment is correctly labelled.<br />

c) There are no prohibited combinati<strong>on</strong>s of adjoining or parallel types of track<br />

circuits.<br />

d) There are no prohibited track circuit equipment combinati<strong>on</strong>s.<br />

e) A wire count is carried out <strong>on</strong> all terminati<strong>on</strong>s, and the wiring proved correct.<br />

Check that:<br />

a) The physical positi<strong>on</strong>s of all IRJs or track ends are correct, especially those<br />

defining overlaps or clearance points.<br />

b) The physical stagger between nominally opposite IRJs does not exceed the<br />

permissible dimensi<strong>on</strong>s, and that no sub–secti<strong>on</strong> of the track circuit is shorter<br />

than the permitted minimum.<br />

c) All rail b<strong>on</strong>ds, rail jumpers, tracti<strong>on</strong> b<strong>on</strong>ds, track circuit interrupters and track<br />

feed/relay cables are in accordance with the b<strong>on</strong>ding plan and scheme plan,<br />