01.05.2013 Views

MicroStrategy Mobile Design and Administration Guide

MicroStrategy Mobile Design and Administration Guide

MicroStrategy Mobile Design and Administration Guide

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3<br />

Administering <strong>MicroStrategy</strong> <strong>Mobile</strong> <strong>Mobile</strong> <strong>Design</strong> <strong>and</strong> <strong>Administration</strong> <strong>Guide</strong><br />

• In UNIX/Linux: After you deploy <strong>MicroStrategy</strong> <strong>Mobile</strong> Server<br />

Universal <strong>and</strong> log on to the mstr<strong>Mobile</strong>Admin servlet using proper<br />

authentication, the <strong>Mobile</strong> Server Administrator web page opens. The<br />

default location of the Administrator servlet varies depending on the<br />

platform that you are using.<br />

2 From the pane on the left, select <strong>Mobile</strong> Configuration.<br />

3 Click Define New Configuration.<br />

4 From the Device drop-down list, select either Android Phone or<br />

Android Tablet to create a configuration for the desired device.<br />

5 In the Configuration Name field, type the name of the configuration.<br />

This is the name that is displayed in the configuration list.<br />

Configure the Android Phone or Android Tablet settings<br />

6 Select either the Phone Settings or Tablet Settings tab.<br />

7 From the Memory Limit drop down list, select the amount of memory<br />

that is available to the application. Values include 25 MB, 50 MB, 100<br />

MB, 250 MB, 500 MB, 1 GB, 2 GB, 3 GB, or 4 GB. The application uses<br />

the lower of this value <strong>and</strong> the available memory on the device. Reports<br />

<strong>and</strong> documents render faster when more memory is available to the<br />

application. The default value is 250 MB.<br />

8 In the Network Timeout field, specify how long, in seconds, the<br />

application should wait for the network to respond before reporting a<br />

timeout. The default value is 60 seconds.<br />

9 In the Maximum Columns in Grid field, specify the maximum number<br />

of columns displayed at one time in a grid report. If the number of<br />

columns in the grid exceeds this value, the user can scroll to see<br />

additional columns. The default value is 10 columns.<br />

10 By default, the maximum canvas to screen ratio is set to 25. This default<br />

setting is ideal for displaying reports <strong>and</strong> documents on most device<br />

screens. Some devices with high screen resolutions can experience<br />

rendering problems with this default setting. To solve rendering<br />

problems for your reports <strong>and</strong> documents on high resolution screens,<br />

lower the value in the Maximum canvas to screen ratio field.<br />

11 In the Check for new subscriptions every field, type how often, in<br />

seconds, the application checks for new versions of subscribed reports<br />

<strong>and</strong> documents on Intelligence Server. The default value is 600 seconds.<br />

136 Deploying <strong>and</strong> configuring the <strong>MicroStrategy</strong> <strong>Mobile</strong> application © 2012 <strong>MicroStrategy</strong>, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!