LC <strong>Manual</strong> 11/02 Rev. 3 SYSTEM INSTALLATION<br />

NOTE: A normally closed switch or switches should be selected. The MC10 Controller<br />

may be used to connect one level switch to the controller (instructions are<br />

included with the MC10 manual located in the Appendix).<br />

C. To connect the accessory, remove the shorting wire where applicable <strong>and</strong><br />

connect a single pole single throw normally closed sensor (TANK SWITCHES<br />

<strong>and</strong> PRETREATMENT INTERLOCK) between the respective terminals; <strong>for</strong><br />

CHEMICAL FEED SYSTEM OUTPUT connect the wires from the chemical feed<br />

system relay (by others). It is recommended that shielded cable, properly<br />

grounded, be used to wire these sensors to avoid radio signal interference with<br />

these functions.<br />

2.9 SETTING THE FLUSH CYCLE TIME AND DURATION<br />

Refer to the MC10 RO Controller manual in the Appendix <strong>for</strong> detailed instructions.<br />

2.10 BEFORE POWER TURN ON<br />

CAUTION<br />

CAUTION<br />

CAUTION<br />

If an isolation valve is located downstream of the RO unit in the product,<br />

reject or autoflush piping, a pressure relief device must be installed to<br />

avoid an over pressurization condition that could irreversibly damage the<br />

RO unit <strong>and</strong> related components.<br />

Verify that all retaining “U” pins are in place on the RO pressure vessels<br />

be<strong>for</strong>e turning on the pump.<br />

Be sure the product water will not enter the user system during startup.<br />

The RO system must be operated <strong>for</strong> four hours to flush out the<br />

preservative solution be<strong>for</strong>e connecting to the user system.<br />

Once the feed water is plumbed to the system <strong>and</strong> the electrical power is connected, the<br />

electrician should verify correct motor rotation.<br />

2.11 INSTALLATION OF REVERSE OSMOSIS MEMBRANE(S)<br />

CAUTION<br />

CAUTION<br />

Never engage or disengage retaining “U” pins without wearing safety<br />

glasses.<br />

Never allow the RO membrane to dry out once it has been wet, or<br />

irreversible damage will result.<br />

USFilter Reverse Osmosis units are normally shipped with the membranes installed <strong>and</strong><br />

preserved in sodium bisulfite solution. However, should the need arise, the following<br />

procedures may be followed to install membranes:<br />

A. Disconnect all tubing from all RO pressure vessel end caps. This is done by<br />

pushing in the outer ring of the quick disconnect fitting while at the same time<br />

pulling the tubing out of the fitting.<br />

USFilter 2-3