Product Description/Equipment Specifications<br />

Vantage Series Reverse Osmosis Units<br />

Model LC<br />

Process Water Systems<br />

General Description<br />

USFilter’s Vantage Series model LC Reverse Osmosis units are designed <strong>and</strong><br />

manufactured <strong>for</strong> commercial applications. Each LC model consists of a single<br />

stage centrifugal pump <strong>and</strong> tap water low pressure membranes. They are preengineered,<br />

pre-assembled units that minimize installation <strong>and</strong> start-up costs.<br />

They are fully tested at the factory <strong>and</strong> only require simple utility connections<br />

(feed water inlet, product water outlet, drains <strong>and</strong> power). They arrive with<br />

membranes installed <strong>and</strong> are ready <strong>for</strong> immediate on-line service with minimal<br />

set up <strong>and</strong> adjustments. Their simple designs maximize reliability of the Reverse<br />

Osmosis unit. An optional modem is available <strong>for</strong> remote operation <strong>and</strong><br />

monitoring to tailor the Vantage Series Reverse Osmosis equipment <strong>for</strong> specific<br />

customer requirements.<br />

Each unit is a single pass RO system mounted on a polyurethane coated<br />

structural steel frame. The RO unit includes a high pressure feed pump, PVC<br />

end entry pressure vessels, <strong>and</strong> spiral wound thin film composite RO<br />

membranes. Each RO unit also includes PVC low pressure piping, high pressure<br />

brass fittings <strong>and</strong> nylon tube <strong>and</strong> fittings, polyethylene tube <strong>and</strong> fittings <strong>for</strong> low<br />

pressure reject, reject recycle <strong>and</strong> product piping, <strong>and</strong> a system controller.<br />

Mechanical Description<br />

The major components are supported by the frame <strong>and</strong> designed in such a way<br />

to provide easy access <strong>for</strong> servicing, maintenance, <strong>and</strong> monitoring system<br />

per<strong>for</strong>mance. The frame is an open style full frame configuration designed to<br />

provide maximum support <strong>and</strong> protection <strong>for</strong> the RO unit’s components <strong>and</strong> allow<br />

access <strong>for</strong> maintenance <strong>and</strong> operation.<br />

The feed piping is schedule 80 PVC. The low pressure reject, product <strong>and</strong> low<br />

pressure reject recycle is Polyethylene tubing. The high pressure manifold is<br />

constructed of threaded brass fittings <strong>and</strong> Nylon tubing <strong>and</strong> fittings. The inlet<br />

piping connection is female pipe thread PVC fittings. The product outlet, reject<br />

<strong>and</strong> autoflush connections are quick connect tube style. All high pressure valves,<br />

reject throttling <strong>and</strong> reject recycle throttling needle valves are brass. Sample<br />

valves are provided <strong>for</strong> the RO unit’s feed <strong>and</strong> product lines. An individual<br />

sample valve is also located on the product line of each pressure vessel <strong>for</strong><br />

analyzing individual vessel per<strong>for</strong>mance. Cleaning connections are provided to<br />

clean the RO membranes <strong>and</strong> pressure vessels. All of the cleaning connections<br />

are quick connect tube fittings.<br />

SV301-LC_rev2.doc Page 1 Rev. 2, 10 Oct 2001