LC <strong>Manual</strong> 11/02 Rev. 3 OPERATING INSTRUCTIONS<br />

3.1 CONTROLS AND INDICATORS<br />

3.0 OPERATING INSTRUCTIONS<br />

The controls <strong>and</strong> indicators used in the operation of the system are outlined in the MC10<br />

RO Controller manual located in the Appendix. The operator must be thoroughly familiar<br />

with the controls <strong>and</strong> their respective functions <strong>for</strong> proper operation <strong>and</strong> in order to<br />

maintain the quality of the product <strong>and</strong> eliminate unnecessary shutdowns.<br />

3.2 INITIAL STARTUP OF REVERSE OSMOSIS SYSTEM<br />

CAUTION<br />

CAUTION<br />

CAUTION<br />

CAUTION<br />

Verify that all RO pressure vessel end cap retaining “U” pins are in place<br />

<strong>and</strong> secure.<br />

Do not run the motor <strong>for</strong> more than 30 seconds backwards or irreversible<br />

pump damage may result.<br />

The membrane feed pressure should not be allowed to exceed 225 psig at<br />

any time during operation.<br />

A. The operator should verify that appropriate pretreatment is in place <strong>and</strong> operating<br />

satisfactorily. Inappropriate or inoperative pretreatment can damage the<br />

membranes.<br />

B. Make all water, electrical, <strong>and</strong> drain connections according to installation<br />

instructions.<br />

C. Divert the outlet of the product water to a convenient drain.<br />

D. Turn on the feed water <strong>and</strong> the electrical power. With product water diverted to<br />

drain, fully open the reject throttling valve <strong>and</strong> close the reject recirculation<br />

throttling valve.<br />

E. Place the controller in the DIRECT FEED mode (refer to the Reverse Osmosis<br />

Controller manual in the Appendix <strong>for</strong> detailed instructions). Press the SYSTEM<br />

START button on the controller keypad to start the system, after a fifteen-second<br />

delay the pump should start.<br />

F. Check <strong>for</strong> proper pump rotation. (Please refer to the Pump In<strong>for</strong>mation, included<br />

in the Appendix of this manual <strong>for</strong> in<strong>for</strong>mation concerning motor rotation <strong>and</strong> any<br />

other electrical requirements.)<br />

G. Set the reject recirculation flow to zero, but do not exceed 225 psig pressure to<br />

the membranes. Open the reject valve further if necessary to avoid over<br />

pressuring the system.<br />

Do not use reject recirculation option <strong>for</strong> the first 4 hours of operation to<br />

speed flush up of the system.<br />

USFilter 3-1