LC <strong>Manual</strong> 11/02 Rev. 3 OPERATING INSTRUCTIONS<br />
Storage tank (if applicable) ready <strong>for</strong> use<br />
IF ALL THE ABOVE CONDITIONS EXIST, THE SYSTEM IS READY TO<br />
START. IF ONE OF THE SETTINGS IS INCORRECT, CORRECT THE<br />
SETTING PRIOR TO PROCEEDING.<br />
B. Verify the Controller is set to the proper operating mode, either TANK FEED or<br />
DIRECT FEED as described in the MC10 RO Controller manual in the Appendix.<br />
C. Press the SYSTEM START button on the Controller. This will start the system.<br />
The inlet solenoid valve will open then the pump will start after a 15 second<br />
delay.<br />
D. Verify that the product, reject, <strong>and</strong> reject recirculation flows are correct. If not,<br />
adjust the pump discharge throttling valve <strong>and</strong> the reject <strong>and</strong> reject recirculation<br />
valves. Refer to the Product Description/Equipment Specifications in the<br />
Appendix <strong>for</strong> design flowrates <strong>and</strong> pressures. Adjustment procedure:<br />
First, adjust the unit to make the correct amount of RO product water by<br />
adjusting the system pressure. This can be accomplished by regulating the<br />
pump discharge throttling valve. Further open the valve to increase the system<br />
operating pressure <strong>and</strong> productivity, further close the valve to reduce the system<br />
operating pressure <strong>and</strong> productivity.<br />
Second, adjust the unit to make the correct amount of reject to drain flow by<br />
adjusting the reject throttling valve. Open the valve to obtain a higher flow rate or<br />
close the valve to reduce the flow rate.<br />
Third, adjust the unit to make the correct amount of reject recirculation flow by<br />
adjusting the reject recirculation throttling valve. Further open the valve to obtain<br />
a higher flow rate or close the valve to reduce the flow rate.<br />
NOTE: This is somewhat of a "balancing act", in that as you close the reject valves, the<br />
product flow increases <strong>and</strong> the reject flow decreases. As you open the pump<br />
discharge-throttling valve, the product <strong>and</strong> the reject flows increase. You may<br />
have to adjust the pump discharge-throttling valve to reestablish the operating<br />
pressure to obtain the correct product flow as established in the first step.<br />
E. Once the RO unit is operating at the parameters outlined in this manual, record<br />
the operating parameters on the “RO Data Collection Form” as described in<br />
Section 4.4, <strong>and</strong> found in the Appendix. It is imperative to record the operating<br />
parameters daily, since RO trouble shooting may require a trended analysis of<br />
the RO operating parameters.<br />
NOTE: If the RO will not start, or can not achieve the correct flows, go to the trouble<br />
shooting section <strong>for</strong> more in<strong>for</strong>mation.<br />
USFilter 3-3