Chapter 8: Nodes, Node Groups, and Interfaces<br />

• In-Band - VNC: Select this item to create a KVM connection to a<br />

node through VNC server software.<br />

See Interfaces for In-Band Connections (on page 95).<br />

Out-of-Band Connections:<br />

• Out-of-Band - KVM: Select this item to create a KVM connection to<br />

a node through a <strong>Raritan</strong> KVM device (KX, KX101, KSX,<br />

IP-Reach, Paragon II).<br />

• Out-of-Band - Serial: Select this item to create a serial connection<br />

to a node through a <strong>Raritan</strong> serial device (SX, KSX).<br />

See Interfaces for Out-of-Band KVM, Out-of-Band Serial<br />

Connections (on page 95).<br />

Power Control Connections:<br />

• Power Control - DRAC: Select this item to create a power control<br />

connection to a Dell DRAC server.<br />

• Power Control - iLO Processor: Select this item to create a power<br />

control connection to an HP iLO/RILOE server.<br />

• Power Control - IPMI: Select this item to create a power control<br />

connection to a node with an IPMI connection.<br />

• Power Control - RSA: Select this item to create a power control<br />

connection to an RSA server.<br />

See Interfaces for DRAC, RSA and ILO Processor Power<br />

Control Connections (see "Interfaces for DRAC, RSA, and ILO<br />

Processor Power Control Connections" on page 96) and<br />

Interfaces for IPMI Power Control Connections (on page 97).<br />

Managed Powerstrip Connections:<br />

• Managed PowerStrip: Select this item to create a power control<br />

connection to a node powered through a <strong>Raritan</strong> PowerStrip or<br />

Dominion PX device.<br />

See Interfaces for Managed Powerstrip Connections (on page<br />

96).<br />

Web Browser Connections:<br />

• Web Browser: Select this item to create a connection to a device<br />

with an embedded Web server.<br />

See Web Browser Interface (on page 98).<br />

3. A default name appears in the Name field depending on the type of<br />

interface you select. You can change the name. This name appears<br />

next to the interface in the Nodes list. See Naming Conventions (on<br />

page 314) for details on CC-SG's rules for name lengths.<br />