Chapter 6: Devices, Device Groups, and Ports<br />

Disconnecting Users<br />

<strong>Admin</strong>istrators can terminate any user's session on a device. This<br />

includes users who are performing any kind of operation on a device, such<br />

as connecting to ports, backing up the configuration of a device, restoring<br />

a device's configuration, or upgrading the firmware of a device.<br />

Firmware upgrades and device configuration backups and restores are<br />

allowed to complete before the user's session with the device is<br />

terminated. All other operations will be terminated immediately.<br />

For Dominion SX devices only, you can disconnect users who are directly<br />

logged into the device as well as those who are connected to the device<br />

via CC-SG.<br />

To disconnect users from a device:<br />

1. Click the Devices tab and select the device from which you want to<br />

disconnect users.<br />

2. Choose Devices > Device Manager > Disconnect Users.<br />

3. Select the users whose session you want to disconnect in the<br />

Disconnect users table.<br />

4. Click Disconnect to disconnect the users from the device.<br />

Special Access to Paragon II System Devices<br />

Paragon II System Controller (P2-SC)<br />

Paragon II System Integration users can add their P2-SC devices to the<br />

CC-SG Devices tree and configure them via the P2-SC <strong>Admin</strong> application<br />

from within CC-SG. See <strong>Raritan</strong>'s Paragon II System Controller User<br />

<strong>Guide</strong> for details on using P2-SC <strong>Admin</strong>.<br />

After adding the Paragon System device (the Paragon System includes<br />

the P2-SC device, connected UMT units, and connected IP-Reach units)<br />

to CC-SG, it appears in the Devices tree.<br />

To access Paragon II System Controller from CC-SG:<br />

1. Click the Device tab, and then select the Paragon II System Controller.<br />

2. Right-click the Paragon II System Controller, and then click Launch<br />

<strong>Admin</strong> to launch the Paragon II System Controller application in a new<br />

browser window. You can then configure the PII UMT units.<br />