Chapter 7: Managed Powerstrips<br />

Configuring PowerStrips Connected to KX, KX2, KX2-101, KSX2, and P2SC<br />

CC-SG automatically detects PowerStrips connected to KX, KX2,<br />

KX2-101, KSX2, and P2SC devices. You can perform the following tasks<br />

in CC-SG to configure and manage PowerStrips connected to these<br />

devices.<br />

• Add a PowerStrip Device Connected to a KX, KX2, KX2-101,<br />

KSX2, or P2SC Device (on page 65)<br />

• Move a KX, KX2, KX2-101, KSX2, or P2SC's PowerStrip to a<br />

Different Port (on page 65)<br />

• Delete a PowerStrip Connected to a KX, KX2, KX2-101, KSX2, or<br />

P2SC Device (on page 66)<br />

Add a PowerStrip Device Connected to a KX, KX2, KX2-101, KSX2, or<br />

P2SC Device<br />

When you add a KX, KX2, KX2-101, KSX2, or P2SC device that is<br />

connected to a PowerStrip to CC-SG, the PowerStrip is added<br />

automatically. The PowerStrip will appear in the Devices tab, beneath the<br />

device to which it is connected.<br />

Next Steps:<br />

1. Configure outlets. See Configuring Outlets on a PowerStrip (on<br />

page 69).<br />

2. Associate each outlet with the node that it powers. See Interfaces for<br />

Managed Powerstrip Connections (on page 96).<br />

Move a KX, KX2, KX2-101, KSX2, or P2SC's PowerStrip to a Different<br />

Port<br />

When you physically move a PowerStrip from one KX, KX2, KX2-101,<br />

KSX2, or P2SC device or port to another KX, KX2, KX2-101, KSX2, or<br />

P2SC device or port, CC-SG automatically detects the PowerStrip and<br />

updates its association to the correct device. You do not have to add the<br />

PowerStrip to CC-SG separately.<br />

Note: When you physically remove a PowerStrip from a P2SC port but do<br />

not connect it to another port, CC-SG does not remove the PowerStrip<br />

from the old port. You must perform a partial or full database reset of the<br />

UMT to which the PowerStrip is connected to remove the PowerStrip from<br />

the Devices tab. See the <strong>Raritan</strong> P2SC User <strong>Guide</strong>.<br />