09.04.2014 Views

To Know How - GROHE

To Know How - GROHE

To Know How - GROHE

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Thermostat shower mixer 19 354 Thermostat bath mixer 19 355<br />

Maintenance instructions<br />

Shut off hot and cold water supply!<br />

Please perform disassembly in specified order. Assemble in reverse order.<br />

Thermostatic compact cartridge:<br />

1. Loosen screw ring using a 34mm tool.<br />

2. If necessary, lever out thermostatic cartridge via<br />

recess.<br />

3. Screw off screw ring.<br />

Observe the correct installation position for the thermostatic<br />

compact cartridge.<br />

Non-return valve:<br />

1. Lever out caps and unscrew and remove screws.<br />

2. Pull off temperature selection handle, shut-off handle<br />

and scale rings.<br />

3. Remove the screw cover.<br />

4. Unscrew and remove screws and remove escutcheon.<br />

5. Unscrew and remove non-return valve using an 8mm<br />

allen key.<br />

Headpart:<br />

1. Lever out cap and unscrew and remove screw.<br />

2. Pull off shut-off handle, scale ring, splined adapter and<br />

economy stop.<br />

3. Unscrew and remove ceramic headpart using a 17mm<br />

open-ended spanner.<br />

Readjustment is necessary after each maintenance operation<br />

on the thermostatic cartridge (s. Seite T 59/T 60).<br />

Maintenance Aquadimmer, s. Seite T 54.<br />

<strong>How</strong> to adjust economy stop, s. Seite T 64.<br />

T 16