Shower System 27 017<br />

Maintenance instructions<br />

Shut off hot and cold water supply!<br />

Please perform disassembly in specified order. Assemble in reverse order.<br />

Thermo element:<br />

1. Lever out cap.<br />

2. Loosen screw.<br />

3. Pull off temperature selection handle.<br />

4. Remove clip.<br />

5. Pull off stop ring.<br />

6. Pull off regulating nut with overload unit.<br />

7. Unscrew and remove thermoelement using a 22mm<br />

open-ended spanner.<br />

Non-return valve:<br />

1. Lever out cap.<br />

2. Push shower rail slider off shower rail.<br />

3. Screw off shower rail.<br />

4. Unscrew and remove screw.<br />

5. Lever out caps (A2) and (B2).<br />

6. Unscrew and remove screws (A1) and (B1) and pull off<br />

shut-off handle (A) and temperature selection handle (B).<br />

7. Lever off escutcheons and unscrew retaining rings<br />

using installation tool.<br />

8. Pull off wall plate.<br />

9. Unscrew and remove non-return valve using a 17mm<br />

socket spanner.<br />

Side Shower:<br />

1. Unscrew and remove screw using a screwdriver.<br />

2. Detach complete spray face plate.<br />

3. Pull off housing.<br />

4. Pull off washer by pressing in the ball.<br />

5. Remove ball.<br />

6. Pull out non-return valve using pliers.<br />

When fitting the washer, the ball must be pressed slightly<br />

into the housing.<br />

Readjustment is necessary after each maintenance operation<br />

on the thermostatic cartridge (s. page B 12).<br />

Maintenance Aquadimmer, s. page B 12.<br />