Europlus E<br />
Infrared-Electronic for wash basin mixer 36 207<br />
Problem Cause Remedy<br />
Water not flowing • Water supply interrupted • Open shut-off valves, service valves<br />
• Filter upstream of solenoid valve blocked • Clean, see Solenoid valve maintenance<br />
• Diaphragm defective<br />
• Replace, see Solenoid valve maintenance<br />
• Solenoid valve defective<br />
• Replace, see Solenoid valve maintenance<br />
• Plug-in connector of solenoid valve without contact • Attach plug-in connector<br />
• Battery discharged<br />
• Replace, see Battery maintenance<br />
Indicator lamp flashing • Battery almost discharged<br />
• Replace, see Battery maintenance<br />
Water flowing • Diaphragm blocked<br />
• Clean, see Solenoid valve maintenance<br />
continuously • Solenoid valve defective<br />
• Replace, see Solenoid valve maintenance<br />
Undesired<br />
water flow<br />
• Detection range of sensor system set too<br />
high for local conditions<br />
• Erroneous activation due to object within<br />
detection range of sensor system<br />
Infrared-Electronic for wash basin mixer with mixer device 36 236<br />
• Reduce range using remote control (special<br />
accessory, Prod. no.: 36 206)<br />
• Install base (special accessories,<br />
Prod. no.: 36 210)<br />
Flow rate too low • Filter, mousseur dirty or diaphragm defective • Replace, see Solenoid valve, filter and mousseur<br />
maintenance<br />
• Service valves not fully open<br />
• Fully open shut-off valves, service valves<br />
• Water supply restricted<br />
• Check supply lines, open service valves<br />
Mixing device<br />
incorrect<br />
• See Flow rate too low<br />
• Limescale on mixer spindle<br />
• Temperature limiter incorrectly set<br />
• Clean, see Mixer spindle maintenance<br />
• Adjust, see Description<br />
Problem Cause Remedy<br />
Water not flowing • Water supply interrupted • Open shut-off valves, service valves<br />
• Filter upstream of solenoid valve blocked • Clean, see Solenoid valve maintenance<br />
• Diaphragm defective<br />
• Replace, see Solenoid valve maintenance<br />
• Solenoid valve defective<br />
• Replace, see Solenoid valve maintenance<br />
• Plug-in connector of solenoid valve without contact • Attach plug-in connector<br />
Indicator lamp<br />
flashing<br />
Water flowing<br />
continuously<br />
• Battery discharged<br />
• Battery almost discharged<br />
• Diaphragm blocked<br />
• Solenoid valve defective<br />
• Replace, see Battery maintenance<br />
• Replace, see Battery maintenance<br />
• Clean, see Solenoid valve maintenance<br />
• Replace, see Solenoid valve maintenance<br />
Special Fittings<br />
Undesired<br />
water flow<br />
• Detection range of sensor system set too<br />
high for local conditions<br />
• Reduce range using remote control<br />
(special accessory, Prod. no.: 36 206)<br />
• Erroneous activation due to object within<br />
detection range of sensor system<br />
• Install base (special accessories,<br />
Prod. no.: 36 210)<br />
Flow rate too low • Filter, mousseur dirty or diaphragm defective • Replace, see Solenoid valve, filter and<br />
mousseur maintenance<br />
• Service valves not fully open<br />
• Fully open shut-off valves, service valves<br />
Mixing device<br />
incorrect<br />
• Water supply restricted<br />
• See Flow rate too low<br />
• Limescale on mixer spindle<br />
• Check supply lines, open service valves<br />
• Clean, see Mixer spindle maintenance<br />
• Adjust, see Description<br />
S 19