Europlus E<br />

Infrared-Electronic for wash basin mixer 36 207<br />

Problem Cause Remedy<br />

Water not flowing • Water supply interrupted • Open shut-off valves, service valves<br />

• Filter upstream of solenoid valve blocked • Clean, see Solenoid valve maintenance<br />

• Diaphragm defective<br />

• Replace, see Solenoid valve maintenance<br />

• Solenoid valve defective<br />

• Replace, see Solenoid valve maintenance<br />

• Plug-in connector of solenoid valve without contact • Attach plug-in connector<br />

• Battery discharged<br />

• Replace, see Battery maintenance<br />

Indicator lamp flashing • Battery almost discharged<br />

• Replace, see Battery maintenance<br />

Water flowing • Diaphragm blocked<br />

• Clean, see Solenoid valve maintenance<br />

continuously • Solenoid valve defective<br />

• Replace, see Solenoid valve maintenance<br />

Undesired<br />

water flow<br />

• Detection range of sensor system set too<br />

high for local conditions<br />

• Erroneous activation due to object within<br />

detection range of sensor system<br />

Infrared-Electronic for wash basin mixer with mixer device 36 236<br />

• Reduce range using remote control (special<br />

accessory, Prod. no.: 36 206)<br />

• Install base (special accessories,<br />

Prod. no.: 36 210)<br />

Flow rate too low • Filter, mousseur dirty or diaphragm defective • Replace, see Solenoid valve, filter and mousseur<br />

maintenance<br />

• Service valves not fully open<br />

• Fully open shut-off valves, service valves<br />

• Water supply restricted<br />

• Check supply lines, open service valves<br />

Mixing device<br />

incorrect<br />

• See Flow rate too low<br />

• Limescale on mixer spindle<br />

• Temperature limiter incorrectly set<br />

• Clean, see Mixer spindle maintenance<br />

• Adjust, see Description<br />

Problem Cause Remedy<br />

Water not flowing • Water supply interrupted • Open shut-off valves, service valves<br />

• Filter upstream of solenoid valve blocked • Clean, see Solenoid valve maintenance<br />

• Diaphragm defective<br />

• Replace, see Solenoid valve maintenance<br />

• Solenoid valve defective<br />

• Replace, see Solenoid valve maintenance<br />

• Plug-in connector of solenoid valve without contact • Attach plug-in connector<br />

Indicator lamp<br />

flashing<br />

Water flowing<br />

continuously<br />

• Battery discharged<br />

• Battery almost discharged<br />

• Diaphragm blocked<br />

• Solenoid valve defective<br />

• Replace, see Battery maintenance<br />

• Replace, see Battery maintenance<br />

• Clean, see Solenoid valve maintenance<br />

• Replace, see Solenoid valve maintenance<br />

Special Fittings<br />

Undesired<br />

water flow<br />

• Detection range of sensor system set too<br />

high for local conditions<br />

• Reduce range using remote control<br />

(special accessory, Prod. no.: 36 206)<br />

• Erroneous activation due to object within<br />

detection range of sensor system<br />

• Install base (special accessories,<br />

Prod. no.: 36 210)<br />

Flow rate too low • Filter, mousseur dirty or diaphragm defective • Replace, see Solenoid valve, filter and<br />

mousseur maintenance<br />

• Service valves not fully open<br />

• Fully open shut-off valves, service valves<br />

Mixing device<br />

incorrect<br />

• Water supply restricted<br />

• See Flow rate too low<br />

• Limescale on mixer spindle<br />

• Check supply lines, open service valves<br />

• Clean, see Mixer spindle maintenance<br />

• Adjust, see Description<br />