Tectron 577 37 713<br />

Maintenance instructions<br />

Shut off water supply!<br />

Please perform disassembly in specified order. Assemble in reverse order.<br />

Battery:<br />

1. Remove screw and cap.<br />

2. Remove battery, check, clean and replace contacts if<br />

necessary.<br />

Solenoid valve<br />

1. Proceed as for Battery maintenance, points 1 and 2.<br />

2. Detach plug-in connector.<br />

3. Remove screws and detach fitting.<br />

4. Remove solenoid valve and filter.<br />

5. Remove seal.<br />

6. Take out piston with spring.<br />

When reinserting, expand and moisten leather<br />

seal and clean groove.<br />

Setting mode<br />

The flow volume can be checked and changed in<br />

setting mode (see Setting the flow<br />

volume). The detection zone of the fitting can be checked.<br />

The indicator lamp in the sensor system of the fitting<br />

illuminates<br />

- in setting mode when the detection zone of the fitting is<br />

reached.<br />

- by an approaching user.<br />

It is possible to set the detection zone via the optional<br />

remote control. Flushing is immediately triggered when<br />

the detection zone is exited again. The minimum delay<br />

time of 10 seconds is not available in setting mode.<br />

<strong>To</strong> activate setting mode, proceed as follows:<br />

Remove battery and replace after 5 seconds. Setting<br />

mode is automatically terminated after 3 minutes.<br />

For information about problems, cause and remedy<br />

please see page D 48.<br />