Aquatower 1000, 2000<br />

Further service notes for: 27 015, 27 017<br />

Aquadimmer:<br />

1. Lever out cap.<br />

2. Unscrew and remove screw, pull off shut-off handle.<br />

3. Remove splined adapter and stop.<br />

4. Unscrew and remove Aquadimmer using a 19mm<br />

open-ended spanner.<br />

Observe the correct installation position.<br />

1. The dissimilar pins (1) and (2) must engage in the<br />

corresponding holes in the race.<br />

2. Fit stop with marking pointing downwards, markings<br />

(3) and (4) align.<br />

3. Fit splined adapter, the faces coincide in only one<br />

position.<br />

4. Turn splined adapter so that the lug points to the right.<br />

Adjusting (temperature selection):<br />

1. Open the cold and hot water supply.<br />

2. Open shut-off handle to hand shower position and<br />

measure temperature of the water using a<br />

thermometer.<br />

3. Turn temperature selection handle until the water<br />

temperature reaches 38 °C.<br />

4. Lever out cap.<br />

5. Hold temperature selection handle in this position and<br />

remove screw.<br />

6. Pull off temperature selection handle and refit so that<br />

the 38°C marking on the wall plate aligns with the<br />

marking on the handle.<br />

7. Screw in screw and fit cap.<br />