Fault-Cause-Remedy<br />

Tectron Skate for flushing cistern GD 2 38 698<br />

Problem Cause Remedy<br />

Indicator lamp on • Obstacle during calibration<br />

front of electronics<br />

flashing continuously<br />

after<br />

calibration<br />

• Servo motor defective<br />

• Perform calibration again ensuring there is<br />

no obstacle in the adjustment range of the<br />

sensor motor, see Maintenance, Calibrating<br />

the servo motor<br />

• Replace servo motor, see Maintenance,<br />

Replacing the servo motor<br />

No flushing<br />

• Water supply interrupted<br />

• No voltage (indicator lamp on rear of electronics<br />

not flashing)<br />

• Electronics defective (indicator lamp not flashing or<br />

permanently on)<br />

• Servo motor defective (rotation will not be executed)<br />

• Plug-in connectors without contact<br />

• The detection zone of the sensor system is set too<br />

low/too high<br />

• Servo motor defective<br />

• Switch on power supply or check plug-in<br />

connection or transformer defective, see<br />

Maintenance, Replacing the transformer<br />

• Replace, see Wall plate with electronics<br />

maintenance<br />

• Replace servo motor, see Maintenance,<br />

Replacing the servo motor<br />

• Attach plug-in connector<br />

• Increase/reduce detection zone using<br />

remote control (special accessories 36 206)<br />

Water flowing<br />

continuously<br />

Undesired<br />

flushing<br />

Flow volume too<br />

low<br />

• Waste valve not closing<br />

• The detection zone of the sensor system is set too<br />

high<br />

• Flow volume set too low<br />

• Waste valve not lifting fully out<br />

• Servo motor defective (rotation will not be<br />

executed)<br />

• Adjust servo motor position, see Maintenance,<br />

Adjusting the servo motor position, or waste valve<br />

defective (replace, repair), see Cistern instructions<br />

• An opposing object is detected. Reduce detection<br />

zone using remote control (special accessories<br />

36 206).<br />

• Adjust flow volume, see Maintenance,Setting the<br />

waste valve to 9 l flow volume<br />

• Adjust servo motor position, see Maintenance,<br />

Adjusting the servo motor position<br />

• Replace servo motor, see Maintenance,<br />

Replacing the servo motor<br />

Flow volume too<br />

high<br />

• Waste valve set to 6 litres<br />

• Flow volume set too high<br />

• Set waste valve to 9 litres, see Maintenance,<br />

Setting the waste valve to 9 l flow volume<br />

• Adjust flow volume, see Setting flow<br />

volume<br />

Setting mode<br />

The flow volume can be checked and changed in setting mode (see Setting the flow volume).<br />

The detection zone of the fitting can be checked. The indicator lamp in the sensor system of the fitting illuminates in<br />

setting mode when the detection zone of the fitting is reached by an approaching user.<br />

It is possible to set the detection zone via the optional remote control. Flushing is immediately triggered when the<br />

detection zone isexited again. The minimum delay time of 7s is not available in setting mode. <strong>To</strong> activate setting<br />

mode, proceed as follows:<br />

Disconnect the power supply to the electronics and reconnect after 5s. The plug connection between the servo<br />

motor and the electronics must not be detached!<br />

Setting mode is activated.<br />

Setting mode is automatically terminated after 3 min.<br />

Sanitary Systems<br />

D 45