Thermostat shower mixer 19 359<br />

Thermostat for bath and/or shower 19 356<br />

Thermostat bath mixer 19 358<br />

Maintenance instructions<br />

Shut off hot and cold water supply!<br />

Please perform disassembly in specified order. Assemble in reverse order.<br />

Thermostatic compact cartridge:<br />

1. Loosen screw ring using a 34mm tool.<br />

2. If necessary, lever out thermostatic cartridge via<br />

recess.<br />

3. Screw off screw ring.<br />

Observe the correct installation position for the thermostatic<br />

compact cartridge.<br />

Non-return valve:<br />

1. Lever out caps and unscrew and remove screws.<br />

2. Pull off temperature selection handle, shut-off handle<br />

and scale rings.<br />

3. Remove escutcheon.<br />

4. Unscrew and remove screws and remove escutcheon<br />

mounting bracket.<br />

5. Unscrew and remove screw plug using an 8mm allen<br />

key.<br />

6. Pull out non-return valve.<br />

Headpart:<br />

1. Lever out cap and unscrew and remove screw.<br />

2. Pull off shut-off handle, scale ring, splined adapter and<br />

economy stop.<br />

3. Unscrew and remove ceramic headpart using a 17mm<br />

open-ended spanner.<br />

Readjustment is necessary after each maintenance operation<br />

on the thermostatic cartridge (s. Seite T 59/T 60).<br />

Maintenance Aquadimmer, s. Seite T 55.<br />

<strong>How</strong> to adjust economy stop, s. Seite T 64.<br />