Thermostat shower mixer 34 027<br />

Maintenance instructions<br />

Shut off hot and cold water supply!<br />

Please perform disassembly in specified order. Assemble in reverse order.<br />

Thermo-element:<br />

1. Pull off temperature selection handle.<br />

2. Remove clip.<br />

3. Pull off stop ring.<br />

4. Pull off regulating nut with overload unit.<br />

5. Unscrew and remove thermoelement using a 22mm<br />

open-ended spanner.<br />

The overload unit must be screwed as far as possible into<br />

the regulating nut (left-hand thread).<br />

Observe the correct installation position of the stop ring.<br />

Non-return valve:<br />

1. Disassemble mixer in reverse order, see Fig. [1].<br />

2. Remove dirt strainer.<br />

3. Remove union nipple using a 12mm allen key by<br />

turning clockwise (left-hand thread).<br />

4. Remove non-return valve.<br />

5. Screw off shower hose and remove non-return valve.<br />

Readjustment is necessary after each maintenance operation<br />

on the thermostatic cartridge. (s. page T 62)<br />