Eurodisc SE<br />

Self-closing basin mixer with mixing device 36 233<br />

Problem Cause Remedy<br />

Water not flowing • Battery without contact • Clean contacts, see Electronic cartridge<br />

maintenance<br />

• Water supply interrupted<br />

• Open shut-off valves<br />

• Filter upstream of solenoid valve blocked • Clean, see Solenoid valve maintenance<br />

• Solenoid valve defective<br />

• Replace, see Solenoid valve maintenance<br />

• Installation mode active<br />

• Press pushbutton cap twice (double-click)<br />

• Battery discharged<br />

• Replace, see Cartridge maintenance<br />

Pulsating water jet • Battery almost discharged • Replace, see Cartridge maintenance<br />

Water flowing • Solenoid valve defective<br />

• Replace, see Solenoid valve maintenance<br />

continuously<br />

Flow rate too low • Water supply restricted • Check supply lines<br />

• Filter upstream of solenoid valve blocked • Replace, see Solenoid valve maintenance<br />

• Filters in the union connection set blocked • Replace, see Non-return valve maintenance<br />

Incorrect mixed<br />

temperature<br />

• Non-return valve defective<br />

• Service valves not fully open<br />

• See "Flow rate too low<br />

• Temperature limiter incorrectly set<br />

• Limescale on mixer spindle<br />

• Replace, see Non-return valve maintenance<br />

• Open shut-off valves, service valves<br />

• Set, see Setting temperaturelimiter<br />

• Clean, see Mixer spindle maintenance<br />

Self-closing shower thermostat 36 244<br />

Problem Cause Remedy<br />

Water not flowing • Battery without contact • Clean contacts, see Electronic cartridge<br />

maintenance<br />

• Water supply interrupted<br />

• Open shut-off valves<br />

• Filter upstream of solenoid valve blocked • Clean, see Solenoid valve maintenance<br />

• Diaphragm defective<br />

• Replace, see Solenoid valve maintenance<br />

• Solenoid valve defective<br />

• Replace, see Solenoid valve maintenance<br />

• Plug-in connector of solenoid valve without<br />

contact<br />

• Installation mode active<br />

• Attach plug-in connectors, see Solenoid valve<br />

maintenance<br />

• Press pushbutton cap twice (double-click)<br />

• Battery discharged<br />

• Replace, see Cartridge maintenance<br />

Pulsating water jet • Battery almost discharged • Replace, see Cartridge maintenance<br />

Water flowing continuously<br />

• Diaphragm blocked<br />

• Clean, see Solenoid valve maintenance<br />

• Solenoid valve defective<br />

• Replace, see Solenoid valve maintenance<br />

Flow rate too low • Water supply restricted • Check supply lines<br />

• Filter upstream of solenoid valve blocked • Replace, see Solenoid valve maintenance<br />

•Filters in the union connection set blocked • Replace, see Non-return valve maintenance<br />

Water temperature • Thermostat not adjusted to local pressure<br />

too high or too low • Non-return valve defective<br />

• Adjust thermostatic cartridge, see Adjusting<br />

• Replace, see Non-return valve maintenance<br />