Maintenance Aquadimmer:<br />

Grohtherm 2000: 34 174<br />

Grohtherm 3000: 34 185<br />

1. Lever out cap and unscrew and remove screw.<br />

2. Pull off shut-off handle, splined adapter and stop.<br />

3. Unscrew and remove Aquadimmer using a 19mm<br />

open-ended spanner.<br />

Observe the correct installation position!<br />

1. The dissimilar pins must engage in the corresponding<br />

holes in the housing.<br />

2. Turn shut-off spindle of the Aquadimmer so that face<br />

points to the front.<br />

3. Fit stop so that the ridges align with the recesses on<br />

the scale ring.<br />

Grohtherm 3000: 34 367<br />

1. Lever out cap and unscrew and remove screw.<br />

2. Pull off shut-off handle, splined adapter and stop.<br />

3. Unscrew and remove Aquadimmer using a 19mm<br />

open-ended spanner.<br />

Observe the correct installation position.<br />

1. The dissimilar pins must engage in the corresponding<br />

holes in the race.<br />

2. Fit stop so that the arrow aligns with the marking on<br />

the housing.<br />

3. Turn shut-off spindle of the Aquadimmer so that face<br />

points to the front.<br />

4. Fit splined adapter that the arrow aligns with the mar<br />

king on the housing.<br />

5. Fit shut-off handle making sure that button faces for<br />

wards.<br />

Grohtherm 3000: 19 665<br />

1. Proceed as for maintenance of non-return valve,<br />

points 1 - 4.<br />

2. Remove splined adapter and stop.<br />

3. Unscrew and remove Aquadimmer using a 19mm<br />

open-ended spanner.<br />

Observe the correct installation position.<br />

1. The dissimilar pins must engage in the corresponding<br />

holes in the housing.<br />

2. Fit stop so that the arrow aligns with the marking on<br />

the cap.<br />

3. Turn shut-off spindle of the Aquadimmer so that face<br />

points upwards.<br />

4. Fit and turn splined adapter so that the arrow aligns<br />

with the marking on the cap.<br />

5. Fit shut-off handle making sure that button faces to the<br />

right.<br />

T 42