Urinal - Electronic 37 749<br />

Flow volume setting<br />

The factory-set flow volume is approx. 3 litres at a flow<br />

pressure of 3 bar.<br />

The flow volume can be changed as follows:<br />

1. Activate setting mode (see above).<br />

2. Hold hand at a distance of approx. 5 - 10cm in front of<br />

the sensor system in the fitting. The indicator lamp<br />

in the sensor system of the fitting flashes quickly.<br />

3. The indicator lamp extinguishes automatically after<br />

approx. 5 s.<br />

4. Remove hand from the detection zone (at least 60cm).<br />

5. Again hold hand at a distance of approx. 5 - 10cm in<br />

front of the sensor system. The flow volumes are<br />

indicated via the indicator lamp in the sensor system<br />

by groups of flashing signals separated by a pause.<br />

6. Flow volumes and display:<br />

The number of flashing signals of the consecutive<br />

groups corresponds to the following flow volumes:<br />

1 = flow volume 1 litre<br />

Pause<br />

2 = flow volume 2 litres<br />

Pause<br />

3 = flow volume 3 litres (factory setting)<br />

Pause<br />

...<br />

7 = flow volume 7 litres<br />

Pause<br />

After the group with 7 flashing signals, the routine starts<br />

from the beginning<br />

1 = flow volume 1 litre<br />

...<br />

7. Selecting the flow volume<br />

The flow volume is selected by removing the hand<br />

from the detection zone (at least 60cm) in the pause<br />

after a group of flashing signals. Once the hand is<br />

removed, the fitting immediately flushes with the<br />

selected flow volume (the corresponding flashing<br />

signals are displayed again during flushing).<br />

8. The flow volume can be readjusted within the next<br />

20 s if necessary by again holding the hand at a<br />

distance of 5 - 10cm in front of the sensor system<br />

(see point 5).<br />

The selected flow volume is accepted as the new setting<br />

and setting mode is automatically terminated if there is<br />

no hand in front of the sensor system within 20 s of<br />

flushing. The area directly in front of the sensor system<br />

must be kept free from objects for these 20 s as otherwise<br />

the flow volume will be unintentionally adjusted<br />

once more.<br />

D 54