Eurodisc SE, Controecon<br />

Further service notes<br />

Adjustment of temperature (36 244):<br />

1. Initiate water flow and measure the temperature of the<br />

water using a thermometer.<br />

2. Turn temperature selection handle until the water<br />

temperature reaches 30 °C.<br />

3. Loosen screw and pull off cap.<br />

4. Unscrew and remove screw and pull off scale handle.<br />

5. Fit scale handle so that the 30 °C marking on the<br />

handle aligns with the marking on the fitting housing<br />

and fasten with a screw.<br />

6. Fit cap and fasten using a screw.<br />

Running time (36 233)<br />

1. Activate adjusting mode by pressing the pushbutton<br />

cap.<br />

2. Keep pushbutton cap pressed; water flow commences<br />

after pressing for 10 s.<br />

3. Release the pushbutton cap after achieving the desired<br />

running time (2 - 60 s).<br />

4. Confirm the set time by pressing the pushbutton cap<br />

twice (double-click) within 2 s.<br />

The running time setting is confirmed by a short water<br />

pulse (1 s).<br />

Running time (36 100)<br />

1. Close water supply.<br />

2. Lock threaded ring and screw off cap.<br />

3. Adjust running time using a screwdriver via internal<br />

adjustment ring.<br />

Turn clockwise = longer running time<br />

Turn anti-clockwise = shorter running time<br />

One turn of the adjustment ring corresponds to<br />

approx. 4 s.<br />

4. Refit cap.<br />