Settings<br />

Temperature end stop:<br />

Auromatic 2000: 34 018, 34 450, 34 692<br />

Temperature end stop<br />

With this thermostat fitting, the hot water end stop can<br />

be set to between 35 °C and 45 °C.<br />

1. Set the temperature to 20 °C.<br />

2. Disassemble cap and temperature control handle.<br />

Important: Regulating nut must not be adjusted.<br />

3. Pull off red end stop and refit with the arrow pointing<br />

to the maximum desired temperature.<br />

4. Fit temperature control handle so that the 20 °C<br />

marking on the handle aligns with the marking dot on<br />

the escutcheon.<br />

5. Install cap.<br />

Auromatic 2000: 34 450, 34 692<br />

Desinfection:<br />

1. Disassemble cap.<br />

2. Turn temperature control handle to the hot water<br />

end stop.<br />

3. Open shut-off valve and allow hot water at a minimum<br />

temperature of 70 °C to run for three minutes.<br />

4. Turn temperature control handle back to cold water<br />

end stop and install cap.<br />

Thermostats<br />

Grohtherm XL: 35 085<br />

Desinfection:<br />

1. Unscrew and remove screw, remove cap.<br />

2. Pull out red safety stop to the stop.<br />

3. Turn temperature control handle to the hot water<br />

end stop.<br />

4. Open draw-off points and allow hot water at a<br />

minimum temperature of 70 °C to run for three<br />

minutes.<br />

5. Turn temperature control handle to the cold water<br />

end stop.<br />

6. Press red safety stop back in.<br />

7. Fit cap and replace screw.<br />

8. Set temperature control handle to the desired mixed<br />

water temperature.<br />

T 45