DAL-Automatic flush valve for WC 37 139<br />

Maintenance instructions<br />

Shut off hot and cold water supply!<br />

Cleaning / surfaces<br />

Do not use any cleaning or scouring agents<br />

containing chlorine. Please make sure to inform<br />

customers of this.<br />

Water escaping at the anti-vacuum device<br />

1. Flush pipe inserted too far into the bowl: Pull out or<br />

shorten flush pipe (Fig. 1).<br />

2. Resistance in the flush pipe caused by constriction or<br />

kinking: Replace flush pipe (Fig. 2).<br />

3. Constriction in the flush water distributor or the flush<br />

nozzles of the WC bowl: Replace WC bowl (Fig. 3).<br />

Pipes making noise<br />

1. Rattling noises during flushing:<br />

Valve cone in the upstream bushing valves loose:<br />

- Tighten or replace valve top.<br />

2. Bang at the end of the flush operation:<br />

- Nozzle dilated: Replace piston (Fig. 4).<br />

- Leather seal defective: Replace.<br />

3. Non-return valve making noise Excessive pressure<br />

drop: Replace defective valve (Fig. 5).<br />

Planning instruction<br />

Make sure the supply pipe (to the flushing valve) is adequately<br />

dimensioned! For 3/4" (WC) flush: Supply pipe at<br />

least 1".<br />

Flow pressure too low (Figs. 6 and 7)<br />

(pressure drop should be max. 1.5 bar)<br />

1. Resistance in the pipe, for example water meter too<br />

small, dirt filter clogged:<br />

Eliminate resistance.<br />

2. Isolating valve in the supply pipe not fully open: Open<br />

valves.<br />

3. Supply pipe inadequately dimensioned: Use cistern.<br />

4. Pressure conditions inadequate (minimum pressure 1.2<br />

bar acc. to DIN 3265):<br />

Use low-pressure flush (above 0.5 bar flow pressure) if<br />

pipe adequately dimensioned.<br />

Flushing valve on the same line flushing without having<br />

been actuated (Fig. 8)<br />

5. Pipe inadequately dimensioned and at the same time<br />

flow pressure too low:<br />

- Increase flow pressure; see above. 1.-2.<br />

- Use low-capacity fitting.<br />

Do not lubricate the functional components of the<br />

fitting!<br />