Fault-Cause-Remedy<br />

Urinal flush valve 37 017<br />

Problem Cause Remedy Abbildung<br />

Continuous • Nozzle blocked • Clean • 7<br />

running / persistent<br />

• Seal on relief cone dirty or damaged • Clean or replace • 10<br />

low<br />

water flow • Piston seal defective • Replace • 8<br />

Flushing too • Leather seal dry or damaged • Expand or replace • 6 + 9<br />

short<br />

• Setting incorrect • Check • 15a + 15b<br />

Water emerging<br />

from under the<br />

pushbutton cap<br />

• Roll-type diaphragm defective • Replace • 11 + 12<br />

Flush flow too<br />

low or too<br />

high<br />

• Flow pressure too low or too high • Adjust • 14<br />

Sanitary Systems<br />

D 51