Designation<br />
Title<br />
C203<br />
Coal-Tar Protective Coatings and Linings for Steel <strong>Water</strong> Pipelines, Enamel and Tape,<br />
Hot-Applied<br />
C205<br />
Cement-Mortar Protective Lining and Coating for Steel <strong>Water</strong> Pipe, 4” and Larger,<br />
Shop Applied<br />
C208<br />
Dimensions for Fabricated Steel <strong>Water</strong> Pipe Fittings<br />
C213<br />
Fusion-Bonded Epoxy Coating for the Interior and Exterior of Steel <strong>Water</strong> Pipelines<br />
C218<br />
Coating the Exterior of Aboveground Steel <strong>Water</strong> Pipelines and Fittings<br />
C219<br />
Bolted, Sleeve-Type Couplings for Plain-End Pipe<br />
C220<br />
Stainless-Steel Pipe, ½” and Larger<br />
C221<br />
Fabricated Steel Mechanical Slip-Type Expansion Joints<br />
C222<br />
Polyurethane Coatings for the Interior and Exterior of Steel <strong>Water</strong> Pipe and Fittings<br />
C224<br />
Nylon-11 Based Polyamide Coating <strong>System</strong> for the Interior and Exterior of Steel <strong>Water</strong><br />
Pipe and Fittings<br />
C226<br />
Stainless Steel Fittings for <strong>Water</strong>works Service, Sizes ½”-72”<br />
Valves/ Hydrants:<br />
C517<br />
Resilient-Seated Cast-Iron Eccentric Plug Valves<br />
C512<br />
Air Release, Air/Vacuum, and Combination Air Valves for <strong>Water</strong>works Service<br />
C561<br />
Fabricated Stainless Steel Slide Gates<br />
C563<br />
Fabricated Composite Slide Gates<br />
C560<br />
Cast-Iron Slide Gates<br />
C502<br />
Dry-Barrel Fire Hydrants<br />
C504<br />
Rubber-Seated Butterfly Valves<br />
C507 Ball Valves, 6”- 48”<br />
C508<br />
Swing-Check Valves for <strong>Water</strong>works Service, 2”- 24” National Pipe Size (NPS)<br />
C509<br />
Resilient-Seated Gate Valves for <strong>Water</strong> Supply ductile iron only<br />
C510<br />
Double Check Valve Backflow Prevention Assembly<br />
C511<br />
Reduced-Pressure Principle Backflow Prevention Assembly<br />
C513<br />
Open-Channel, Fabricated-Metal, Slide Gates and Open-Channel, Fabricated-Metal<br />
Weir Gates<br />
C515<br />
Reduced-Wall, Resilient-Seated Gate Valves for <strong>Water</strong> Supply Service (Does not meet<br />
<strong>City</strong> Spec, but can be used in special cases)<br />
C540<br />
Power-Actuating Devices for Valves and Slide Gates<br />
C550<br />
Protective Epoxy Interior Coatings for Valves and Hydrants<br />
Pipe Installation:<br />
C600<br />
Installation of Ductile-Iron <strong>Water</strong> Mains and Their Appurtenances<br />
C602<br />
Cement-Mortar Lining of <strong>Water</strong> Pipelines in Place—4” and Larger<br />
C606<br />
Grooved and Shouldered Joints<br />
Disinfection<br />
C651<br />
Disinfecting <strong>Water</strong> Mains<br />
C652<br />
Disinfection of <strong>Water</strong>-Storage Facilities<br />
Storage<br />
D104<br />
Automatically Controlled, Impressed-Current Cathodic Protection for the Interior of<br />
Steel <strong>Water</strong> Tanks<br />
D110<br />
Wire- and Strand-Wound, Circular, Pre-stressed Concrete <strong>Water</strong> Tanks<br />
D100<br />
Welded Carbon Steel Tanks for <strong>Water</strong> Storage<br />
D102<br />
Coating Steel <strong>Water</strong>-Storage Tanks<br />
D103<br />
Factory-Coated Bolted Steel Tanks for <strong>Water</strong> Storage<br />
D115<br />
Tendon-Pre-stressed Concrete <strong>Water</strong> Tanks<br />
D120<br />
Thermosetting Fiberglass-Reinforced Plastic Tanks<br />
D130<br />
Flexible-Membrane Materials for Potable <strong>Water</strong> Applications<br />